Titan SGS
Staple, Implantable. 510(k) K210278, from Standard Bariatrics (Cincinnati, OH). Product code GDW, class 2.
As of Nov 17, 2026, K210278 is an FDA 510(k) held by Standard Bariatrics, substantially equivalent on Apr 28, 2021 after 86 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Apr 28, 2021
- Review time: 86 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Titan SGS linear cutter is intended for longitudinal transection and resection of gastric tissue for sleeve gastrectomy pouch creation.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Echelon Flex Powered Plus Articulating Endoscopic Linear Cutter, 60MM, Standard, Echelon Flex Powered Plus ArticulatingK140560 · Ethicon Endo-Surgery, LLC · Apr 22, 2014
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Standard Staple-Line Reinforcement (SSLR23)K231603 · Standard Bariatrics, Inc. · Oct 6, 2023
Other GDW Clearances
The newest 510(k)s for the same product code; their median review was 132 days; see every GDW device- Tendon AnchorK263461 · Smith & Nephew, Inc. · Oct 27, 2026
- easyEndo E-Lite Single Use Powered Endoscopic Staplers; easyEndo E-Lite Single Use Powered Endoscopic Staplers with…K254291 · Ezisurg Medical Co., Ltd. · Sep 25, 2026
- ETHICON Circular Stapler (CDH21mm); ETHICON Circular Stapler (CDH25mm); ETHICON Circular Stapler (CDH29mm); ETHICON…K260196 · Ethicon Endo-Surgery, LLC · May 11, 2026
- Tri-staple 2.0 Reloads; Endo GIA Reloads with Tri-Staple Technology; Endo GIA Gray Articulating Reloads; Signia…K253657 · Covidien (Part of Medtronic) · Apr 10, 2026
- ETHICON 4000 45mm Compact Stapler (EC3DT45C); ETHICON 4000 45mm Standard Stapler (EC3DT45S); ETHICON 4000 45mm Long…K252739 · Ethicon Endo-Surgery, LLC · Dec 17, 2025
- ETHICON 4000 60mm Compact Stapler (EC3D60C); ETHICON 4000 60mm Standard Stapler (EC3D60S); ETHICON 4000 60mm Long…K250835 · Ethicon Endo-Surgery, LLC · May 14, 2025
- ECHELON LINEAR Stapler 30mm Stapler (GTX30); ECHELON LINEAR Stapler 60mm Stapler (GTX60); ECHELON LINEAR Stapler…K243276 · Ethicon Endo-Surgery, LLC · Feb 25, 2025
- ECHELON 4000 60mm Compact Stapler (EC3D60C); ECHELON 4000 60mm Standard Stapler (EC3D60S); ECHELON 4000 60mm Long…K241630 · Ethicon Endo-Surgery, LLC · Oct 28, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 1, 2021
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files