Arca
Skip to content
Tools
Tools

GPC 2.4mm Variable Angle Locking Twon Column Volar Distal Radius Plates, 6 head Holes, GPC 2.4mm Variable Angle Locking Two Column Volar Distal Radius Plates, 7 Head Holes, 2.4 mm Variable Angle Locking Two Column Volar Distal Radius Plate-Narrow, 6 Head Holes, Variable Angle Locking Screw 2.4 mm, Stardrive

Plate, Fixation, Bone. 510(k) K210198, from Gpc Medical Limited (New Delhi, IN). Product code HRS, class 2.

As of Nov 18, 2026, K210198 is an FDA 510(k) held by Gpc Medical Limited, substantially equivalent on Jan 7, 2022 after 347 days, with no recalls tied to it in FDA's recall database.

  • Substantially equivalent: Jan 7, 2022
  • Review time: 347 days
  • Recalls: 0

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

GPC Variable Angle Locking Two Column Volar Distal Radius Plating System is provided non-sterile. GPC Variable Angle Locking Two Column Volar Distal Radius Plating System is intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones. The system is indicated for use in adult patients only. All implants are for single use only.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Other HRS Clearances

The newest 510(k)s for the same product code; their median review was 79 days; see every HRS device

Record

Type
Traditional
Received
Jan 25, 2021
Review panel
Orthopedic
Regulation
21 CFR 888.3030

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files