Arca
Skip to content
Tools
Tools

ELEOS Limb Salvage System with BioGrip

Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented. 510(k) K203815, from Onkos Surgical (Parsippany, NJ). Product code JDI, class 2.

As of Nov 21, 2026, K203815 is an FDA 510(k) held by Onkos Surgical, substantially equivalent on Jun 9, 2021 after 162 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 162 days
  • Recalls: 3

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

ELEOSTM Limb Salvage System Hip Components: Indicated for use in total hip arthroplasty for reduction or relief of pain and/or improved hip function in skeletally mature patients with the following conditions: 1) Non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis, ankylosis, protrusion acetabuli, and painful hip dysplasia; 2) Inflammatory degenerative joint…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K203815, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Dec 22, 2023Z-1818-2025, Z-1817-2025Mislabeling of 13mm Modular Segmental Stem package (HC-13120-03M) which included an implant that was 15mm in diameter (HC-15120-03M) instead of being 13mm as stated on the package. The corresponding 15mm cemented stems…Open
Sep 1, 2023Z-1883-2025Potential for breach of Tyvek seals.Open

Other JDI clearances

The newest 510(k)s for the same product code; their median review was 219 days; see every JDI device

Record

Type
Traditional
Received
Dec 29, 2020
Review panel
Orthopedic
Regulation
21 CFR 888.3350

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.