BriefCase
Radiological Computer-Assisted Triage And Notification Software. 510(k) K203508, from Aidoc Medical , Ltd. (Tel-Aviv, IL). Product code QAS, class 2.
As of Nov 18, 2026, K203508 is an FDA 510(k) held by Aidoc Medical , Ltd., substantially equivalent on Dec 29, 2020 after 29 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Dec 29, 2020
- Review time: 29 days
- Recalls: 0
- Cited as a predicate by: 8 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFBriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of cervical spine CT images. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspected positive findings of linear lucencies in the cervical spine bone in patterns compatible with…
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- BriefCaseK190896 · Aidoc Medical , Ltd. · May 31, 2019
- BriefCaseK180647 · Aidoc Medical , Ltd. · Aug 1, 2018
- BriefCaseK190072 · Aidoc Medical , Ltd. · Apr 15, 2019
- BriefCaseK193298 · Aidoc Medical , Ltd. · Jun 19, 2020
- BriefCaseK201020 · Aidoc Medical , Ltd. · Aug 26, 2020
- BriefCaseK192383 · Aidoc Medical , Ltd. · Dec 20, 2019
Cited as a Predicate
8 later 510(k) summaries name this device as a predicate- BriefCase-TriageK242837 · Aidoc Medical , Ltd. · Oct 18, 2024
- BriefCaseK222277 · Aidoc Medical , Ltd. · Aug 26, 2022
- BriefCaseK221330 · Aidoc Medical , Ltd. · Nov 18, 2022
- BriefCaseK221314 · Aidoc Medical , Ltd. · Jun 3, 2022
- BriefCaseK221240 · Aidoc Medical , Ltd. · May 17, 2022
- BriefCaseK220709 · Aidoc Medical , Ltd. · Oct 7, 2022
- BriefCaseK213886 · Aidoc Medical , Ltd. · Apr 26, 2022
- BriefCaseK213721 · Aidoc Medical , Ltd. · Mar 21, 2022
Other QAS Clearances
The newest 510(k)s for the same product code; their median review was 104 days; see every QAS device- Efai Neurosuite Cta Lvo Assessment System (LVO-CTA-100)K263109 · Ever Fortune.Ai, Co., Ltd. · Oct 30, 2026
- Rapid ICH (v4.0)K262301 · Ischemaview, Inc. · Oct 9, 2026
- a2z-Abdo-TriageK260906 · A2z Radiology Ai, Inc. · Sep 16, 2026
- Rapid Vessel Occlusion (Rapid VO)K261085 · iSchemaview · Jul 13, 2026
- Vascular Assist Occlusion Triage (VAOT) (v1.0)K260729 · GuideAI Health · Jun 18, 2026
- BriefCase-TriageK261317 · Aidoc Medical , Ltd. · May 14, 2026
- Efai Ersuite Ct Appendicitis Assessment System (APPEN-CT-100)K253163 · Ever Fortune.Ai, Co., Ltd. · Apr 22, 2026
- Jlk-NcctK252421 · JLK, Inc. · Mar 24, 2026
Elsewhere
- On FDA's list of AI-enabled devicesFDA AI-enabled medical devices
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Nov 30, 2020
- Review panel
- Radiology
- Regulation
- 21 CFR 892.2080
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files