Arthrex TightRope II
Fastener, Fixation, Nondegradable, Soft Tissue. 510(k) K202581, from Arthrex, Inc. (Naples, FL). Product code MBI, class 2.
As of Nov 21, 2026, K202581 is an FDA 510(k) held by Arthrex, Inc., substantially equivalent on Nov 4, 2020 after 57 days, with no recalls tied to it in FDA's recall database.
- Review time: 57 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The Arthrex TightRope II is intended to be used for fixation of bone to bone or soft tissue to bone, and is intended as fixation posts, a distribution bridge, or for distributing suture tension over areas of ligament or tendon repair. Specifically, Arthrex will be offering these for ACL/PCL Repair and Reconstruction.
- Acl Tightrope,Acl Tightrope Duuble BundleK112990 · Arthrex, Inc. · Dec 19, 2011
- Strut Suture; No-Tie ButtonK253693 · Riverpoint Medical, LLC · Mar 11, 2026
- Bolo Button SystemK242091 · Fusion Orthopedics · Dec 23, 2024
- Arthrex ACL TightRope®, PCL TightRope®, and TightRope® IIK221128 · Arthrex, Inc. · Oct 5, 2022
- Arthrex FiberButtonK263477 · Arthrex, Inc. · Oct 27, 2026
- Q-FIX KNOTLESS All-Suture Anchor, 1.8mm, with one ULTRABRAID Suture, Blue; Q-FIX KNOTLESS All-Suture Anchor, 1.8mm,…K263348 · Smith & Nephew, Inc. · Oct 23, 2026
- TeKBrace Knotless AnchorK263352 · TheraMicro · Oct 21, 2026
- Integrity Retractable Implant Inserter (6000127)K261869 · Anika Therapeutics, Inc. · Sep 17, 2026
- Aevumed SUPERCYNCH™ Button SystemK253065 · Aevumed, Inc. · Sep 2, 2026
- ArthroTAK Tendon Anchor KitK262809 · ArthroTAK, LLC · Sep 2, 2026
- Iconix Knotless TK262677 · Riverpoint Medical · Aug 27, 2026
- Grappler Suture Anchor SystemK262047 · Paragon 28, Inc. · Aug 3, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 8, 2020
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3040
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files