BioFire RP2.1/RP2.1plus Control Panel M441
Assayed External Control Material For Microbiology Nucleic Acid Amplification (Nat) Assays. 510(k) K202196, from Maine Molecular Quality Controls, Inc. (Saco, ME). Product code PMN, class 2.
As of Nov 20, 2026, K202196 is an FDA 510(k) held by Maine Molecular Quality Controls, Inc., substantially equivalent on Jun 24, 2021 after 323 days, with no recalls tied to it in FDA's recall database.
- Review time: 323 days
- Recalls: 0
- Cited as a predicate by: 2 devices
BioFire RP2.1/RP2.1plus Control Panel M441 is intended for use as an external positive and negative assayed quality control to monitor the performance of in vitro laboratory nucleic acid testing procedures for the qualitative detection of Adenovirus, Coronavirus, Human Metapneumovirus, Human Rhinovirus/ Enterovirus, Influenza A, Influenza A subtype H1, Influenza A subtype H1-2009, Influenza A…
- FilmArray RP2/RP2plus Control PanelK173171 · Maine Molecular Quality Controls, Inc. · Nov 24, 2017
- FilmArray GI Control Panel M238K251526 · Maine Molecular Quality Controls, Inc. · Aug 14, 2025
- SPOTFIRE RSP Positive Control, SPOTFIRE RSP Negative ControlK221253 · Maine Molecular Quality Controls, Inc. · Feb 3, 2023
- BioFire Warrior Panel Control KitK262842 · BioFire Defense, LLC · Nov 4, 2026
- eplex RP3 Control M530; eplex RP3 NegativeK263232 · Maine Molecular Quality Controls, Inc. · Oct 30, 2026
- SPOTFIRE VG Control Panel M534, SPOTFIRE VG Negative ControlK262573 · Maine Molecular Quality Controls, Inc. · Oct 21, 2026
- BIOFIRE® FILMARRAY® Tropical Fever Panel Control KitK261475 · Biofire Defense, LLC · Jul 17, 2026
- FilmArray TF Control Panel M527K260577 · Maine Molecular Quality Controls, Inc. · May 19, 2026
- MDx-Chex for BCPK260041 · Streck, LLC · Mar 27, 2026
- MDx-Chex for BCNK254166 · Streck · Mar 23, 2026
- MDx-Chex for BCYK254167 · Streck, LLC · Mar 17, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 5, 2020
- Review panel
- Microbiology
- Regulation
- 21 CFR 866.3920
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files