KMTI Hip Replacement System, Tesera Trabecular Technologies (T3) Acetabular Shell System, Porous Acetabular Cup System
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented. 510(k) K201660, from Kyocera Medical Technologies, Inc. (Redlands, CA). Product code OQG, class 2.
As of Nov 17, 2026, K201660 is an FDA 510(k) held by Kyocera Medical Technologies, Inc., substantially equivalent on Jul 16, 2020 after 28 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jul 16, 2020
- Review time: 28 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe KMTI Hip Replacement System is indicated for patients suffering from: 1. Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis; 2. Rheumatoid arthritis; 3. Correction of functional deformity; 4. Treatment of non-union, femoral neck fracture and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques; and 5.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Tesera Trabecular Technologies (T3) Acetabular Shell System, Porous Acetabular Cup SystemK200328 · Kyocera Medical Technologies, Inc. · Mar 11, 2020
- Renovis Tesera Trabecular Technology (T3) Acetabular Shell SystemK132312 · Renovis Surgical Technologies, LLC · Apr 11, 2014
- Renovis Surgical Porous Acetabular Cup SystemK141676 · Renovis Surgical Technologies, Inc. · Nov 4, 2014
Other OQG Clearances
The newest 510(k)s for the same product code; see every OQG device- Prime and DYNASTY® Additive Manufacturing ShellsK202705 · Microport Orthopedics, Inc. · Aug 20, 2021
- KMTI Hip Replacement SystemK203472 · Kyocera Medical Technologies, Inc. · Apr 2, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 18, 2020
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3358
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files