Visage Breast Density
Automated Radiological Image Processing Software. 510(k) K201411, from Visage Imaging GmbH (Berlin, DE). Product code QIH, class 2.
As of Nov 18, 2026, K201411 is an FDA 510(k) held by Visage Imaging GmbH, substantially equivalent on Jan 29, 2021 after 246 days, with no recalls tied to it in FDA's recall database.
- Review time: 246 days
- Recalls: 0
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFVisage Breast Density is a software application intended for use with compatible full field digital mammography and digital breast tomosynthesis systems. Visage Breast Density assesses breast density from a mammography study and provides an ACR BI-RADS Atlas 5th Edition breast density category to aid radiologists in the assessment of breast tissue composition.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- PowerLook Density Assessment SoftwareK180125 · Icad, Inc. · Apr 5, 2018
- Visage Pacs, Version 6.0/CS 3.1K082269 · Visage Imaging, Inc. · Dec 12, 2008
Other QIH clearances
The newest 510(k)s for the same product code; their median review was 134 days; see every QIH device- Clever OneK260372 · Ewoosoft Co., Ltd. · Nov 4, 2026
- PeekMed® webK262667 · Peek Health, S.A. · Nov 4, 2026
- CINA-Aneurysm+K262147 · Avicenna.Ai · Oct 19, 2026
- Ligence HeartK261733 · UAB Ligence · Oct 7, 2026
- NeuroDRK262134 · Deep Reasoning Ai, Inc. · Oct 7, 2026
- QGuideCT (1.0)K260523 · Medis Medical Imaging Systems BV · Oct 5, 2026
- syngo.CT Brain QuantificationK260055 · Siemens Medical Solutions USA, Inc. · Sep 25, 2026
- BoneXpertK262390 · Visiana · Sep 22, 2026
Elsewhere
- On FDA's list of AI-enabled devicesFDA AI-enabled medical devices
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 28, 2020
- Review panel
- Radiology
- Regulation
- 21 CFR 892.2050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files