LUX-Dx Insertable Cardiac Monitor, myLUX Software Mobile Application, LUX-Dx Clinic Assistant Software, Application Server Device Services (DS) - US
Recorder, Event, Implantable Cardiac, (With Arrhythmia Detection). 510(k) K193473, from Boston Scientific Corporation (St Paul, MN). Product code MXD, class 2.
As of Nov 19, 2026, K193473 is an FDA 510(k) held by Boston Scientific Corporation, substantially equivalent on Jun 26, 2020 after 193 days, with no recalls tied to it in FDA's recall database.
- Review time: 193 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The LUX-Dx Insertable Cardiac Monitor (ICM) is intended to monitor and record subcutaneous ECG (S-ECG) for the clinical evaluation and diagnosis of cardiac arrhythmias. The LUX-Dx is indicated for use in patients that have a known heart condition, are at risk of developing an abnormal heart rhythm, or have symptoms that may suggest a heart condition such as dizziness, palpitations, syncope, chest…
- Reveal Linq Insertable Cardiac MonitorK132649 · Medtronic, Inc. · Feb 14, 2014
- LUX-Dx II (M302); LUX-Dx II+ (M312)K231328 · Boston Scientific Corp · Aug 19, 2023
- LUX-Dx Insertable Cardiac MonitorK210608 · Boston Scientific Corporation · May 25, 2021
- LINQ II Insertable Cardiac Monitor (ICM) (LNQ22)K262735 · Medtronic, Inc. · Aug 28, 2026
- Biomonitor Iv (471155)K261074 · Biotronik, Inc. · May 1, 2026
- Assert-IQ (DM5100)K253516 · Abbott Medical · Dec 18, 2025
- Assert-IQ (DM5000); Assert-IQ (DM5300); Assert-IQ (DM5500); Merlin.net (MN7000)K251221 · Abbott · Sep 17, 2025
- LUX-Dx II Insertable Cardiac Monitor (M302); LUX-Dx II+ Insertable Cardiac Monitor (M312)K252593 · Boston Scientific Corporation · Sep 12, 2025
- LINQ II™ Insertable Cardiac Monitor (ICM)K240693 · Medtronic, Inc. · Mar 28, 2024
- LINQ II Insertable Cardiac MonitorK233562 · Medtronic, Inc. · Dec 6, 2023
- LINQ II™ Insertable Cardiac Monitor (LNQ22)K233320 · Medtronic, Inc. · Oct 31, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 16, 2019
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1025
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files