Glucose HK Gen.3, ISE indirect Na for Gen.2, Elecsys TSH, cobas pro integrated solutions

Hexokinase, Glucose. 510(k) K191899, from Roche Diagnostics (Indianapolis, IN). Product code CFR, class 2.

As of Nov 19, 2026, K191899 is an FDA 510(k) held by Roche Diagnostics, substantially equivalent on Aug 16, 2019 after 31 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 31 days
  • Recalls: 3
  • Cited as a predicate by: 4 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The cobas pro integrated solutions is an IVD device used for the quantitation of clinical chemistry/ immunochemistry and Ion Selective Electrolyte parameters from various biological fluids. Glucose HK Gen.3 is an in vitro test for the quantitative determination of glucose in human serum, plasma, urine and CSF on Roche/Hitachi cobas c systems.

Cited as a predicate

4 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K191899, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Jan 20, 2026Z-1476-2026Software defect, which allows the system to accept erroneous, non-monotonous calibrations for Spline-type assays. Cobas pro integrated solutions is an automated analyzer, intended for running qualitative,…Open
Dec 8, 2020Z-0755-2021Potential for Changed Configuration Settings on the cobas 8000 modular analyzer series/cobas pro integrated solutions, may cause incorrect results in several affected parameters. In the case of poor sample quality,…Open
Nov 23, 2020Z-0752-2021During the subsequent pipetting (1st or 2nd measurement), the residual reagent can sporadically be transferred from the conus into the reaction cuvette and lead to inaccurately low results for the affected TDMs…Terminated

Other CFR clearances

The newest 510(k)s for the same product code; their median review was 111 days; see every CFR device

Record

Type
Traditional
Received
Jul 16, 2019
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1345

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files