VITROS XT Chemistry Products GLU-Ca Slides
Glucose Oxidase, Glucose. 510(k) K190520, from Ortho-Clinical Diagnostics, Inc. (Rochester, NY). Product code CGA, class 2.
As of Nov 19, 2026, K190520 is an FDA 510(k) held by Ortho-Clinical Diagnostics, Inc., substantially equivalent on Apr 3, 2019 after 30 days, with no recalls tied to it in FDA's recall database.
- Review time: 30 days
- Recalls: 0
For in vitro diagnostic use only The GLU test within the VITROS XT Chemistry Products GLU-Ca Slides quantitatively measures glucose (GLU) concentration in serum, plasma, urine, and cerebrospinal fluid using VITROS XT 7600 Integrated Systems.
- VITROS Chemistry Products Cl-Slides, VITROS Chemistry Products ECO2 Slides, VITROS Chemistry Products GLU SlidesK182072 · Ortho-Clinical Diagnostics, Inc. · Oct 30, 2018
- Vitros Chemistry Products: Ca Slides (Model: 145 0261), Calibrators Kit 1 (Model: 188 2208)K072440 · Ortho-Clinical Diagnostics, Inc. · Sep 20, 2007
- ABL90 FLEX PLUS SystemK252488 · Radiometer Medicals Aps · May 1, 2026
- YSI 2900C Biochemistry AnalyzerK210933 · Ysi, Inc. · Sep 30, 2024
- EasyStat 300K220328 · Medica Corporation · Jul 26, 2024
- i-STAT G cartridge with the i-STAT 1 SystemK223755 · Abbott Point of Care, Inc. · Sep 11, 2023
- i-STAT CG8+ cartridge with the i-STAT 1 SystemK223710 · Abbott Point of Care, Inc. · Jul 28, 2023
- GEM Premier ChemSTATK223090 · Instrumentation Laboratory CO · Jan 27, 2023
- Nova Primary Glucose Analyzer SystemK203549 · Nova Biomedical Corporation · Oct 18, 2022
- i-STAT CHEM8+ cartridge with the i-STAT 1 SystemK210958 · Abbott Point of Care, Inc. · Aug 13, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 4, 2019
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1345
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files