Smart-C
Image-Intensified Fluoroscopic X-Ray System, Mobile. 510(k) K190024, from Turner Imaging Systems, Inc. (Orem, UT). Product code OXO, class 2.
As of Nov 18, 2026, K190024 is an FDA 510(k) held by Turner Imaging Systems, Inc., substantially equivalent on Sep 27, 2019 after 263 days, with no recalls tied to it in FDA's recall database.
- Review time: 263 days
- Recalls: 0
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe Smart-C is a mini C -arm X-ray system designed to provide physicians with real time general fluoroscopic visualization of adult and pediatric patients. It is intended to aid physicians and surgeons during diagnostic procedures, therapeutic treatment, or surgical procedures of the limbs, extremities, or shoulders including but not limited to, orthopedics and emergency medicine.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Orthoscan Mobile Di Mini C-ArmK113708 · Orthoscan, Inc. · Jan 5, 2012
Other OXO clearances
The newest 510(k)s for the same product code; their median review was 152 days; see every OXO device- Digital C-ARM with 3DK253296 · Allengers Medical Systems Limited · Jun 5, 2026
- Orthoscan TAU MVP Mini C-Arm SystemK252579 · Ziehm-Orthoscan, Inc. · Jan 14, 2026
- OEC One CFDK253269 · Ge Hualun Medical Systems Co. , Ltd. · Nov 26, 2025
- Dual-Mode Mobile C-Arm (Geelin500A, Geelin500M)K251004 · Hefei Chimed Intelligent Machine Co., Ltd. · Nov 6, 2025
- Orthoscan TAU Mini C-ArmK250587 · Ziehm-Orthoscan, Inc. · Jul 2, 2025
- Orthoscan VERSA Mini C-ArmK243452 · Ziehm-Orthoscan, Inc. · Jan 14, 2025
- OEC One ASDK240828 · Ge Hualun Medical Systems Co. , Ltd. · Dec 27, 2024
- Oec 3DK233669 · Ge Oec Medical Systems, Inc. · Mar 28, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated
- Received
- Jan 7, 2019
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files