EkoSonic Endovascular Device with Control Unit 4.0

Mechanical Thrombolysis Catheter. 510(k) K183361, from Btg International, Inc. (Bothell, WA). Product code QEY, class 2.

As of Nov 20, 2026, K183361 is an FDA 510(k) held by Btg International, Inc., substantially equivalent on Apr 5, 2019 after 122 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 122 days
  • Recalls: 2
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The EkoSonic Endovascular Device with Control Unit 4.0 is indicated for the: - Ultrasound facilitated, controlled and selective infusion of physician-specified fluids, including thrombolytics, into the vasculature for the treatment of pulmonary embolism. - Infusion of solutions into the pulmonary arteries.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K183361, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Oct 13, 2022Z-0149-2023Consoles were shipped without an instruction for use (IFU) or with the incorrect IFU.Open
Nov 3, 2020Z-0637-2021This is a follow-up to the EKOS Field Safety Notice dated April 30, 2019. The Radio Frequency (RF) board has been redesigned to prevent occasional internal board failures at lower temperatures. All EKOS CU 4.0 consoles…Open

Other QEY clearances

The newest 510(k)s for the same product code; their median review was 151 days; see every QEY device

Record

Type
Traditional
Received
Dec 4, 2018
Review panel
Cardiovascular
Regulation
21 CFR 870.5150

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files