Zenition 50
Interventional Fluoroscopic X-Ray System. 510(k) K183101, from Philips Medical Systems Nederland B.V. (Best Noord-Brabant, NL). Product code OWB, class 2.
As of Nov 21, 2026, K183101 is an FDA 510(k) held by Philips Medical Systems Nederland B.V., substantially equivalent on Dec 31, 2018 after 54 days, with 6 recalls tied to it in FDA's recall database.
- Review time: 54 days
- Recalls: 6
- Cited as a predicate by: 1 device
The Zenition 50 device is intended to be used and operated by: adequately trained, qualified and authorized health care professionals who have full understanding of the safety information and emergency procedures as well as the capabilities and functions of the device.
- Philips BV Pulsera/EnduraK010435 · Philips Medical Systems, Inc. · Mar 12, 2001
- StentBoost MobileK203623 · Philips India Limited · Apr 5, 2021
| Sep 29, 2025 | Z-0241-2026Over time some systems may experience loss of imaging functionality and/or poor image quality due to potential corrosion of the Image Intensifier Television (IITV) control board. | Open |
| Feb 25, 2025 | Z-1580-2025A wireless foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation. | Open |
| Oct 7, 2024 | Z-0352-2025Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure. | Open |
| Oct 4, 2023 | Z-0226-2024Philips has become aware of an issue with the Philips Integris-Allura, Allura Xper and Azurion systems that have been delivered to Puerto Rico without a warning label and the Source-to-Skin Distance Spacer (Tube-spacer)… | Open |
| Dec 2, 2021 | Z-0647-2022Firm discovered that the wireless foot switch can suddenly stop responding due to a firmware issue. If the wireless foot switch fails, there could be a delay or interruption of procedure if the hand switch is not used… | Open |
| Apr 10, 2020 | Z-1932-2020When strain relief is lost at the stand side of the Stand MVS Trolley Cable, over time one or more electrical contacts could break due to pulling, twisting, or dropping of the connector. If this happens, live parts may… | Terminated |
- uAngio AVIVA CXK253726 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 21, 2026
- Extron 3;Extron 6K261413 · DRTECH Corporation · Aug 19, 2026
- Zenition 30K254205 · Philips Medical Systems Nederland B.V. · Aug 7, 2026
- Shield System (Siemens 30x40)K260607 · Radiaction , Ltd. · Jul 31, 2026
- SmartCT (R3.0 (L10))K253670 · Philips Medical Systems B.V. · Jul 10, 2026
- C-beamK252735 · Pulmera, Inc. · May 22, 2026
- Intelligent NRK252503 · Canon, Inc. · Apr 30, 2026
- ARTIS icono floor; ARTIS icono biplane; ARTIS icono ceiling; ARTIS phenoK254173 · Siemens Medical Solutions USA, Inc. · Apr 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated
- Received
- Nov 7, 2018
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files