Monaco RTP System
System, Planning, Radiation Therapy Treatment. 510(k) K183037, from Elekta, Inc. (Maryland Heights, MO). Product code MUJ, class 2.
As of Nov 20, 2026, K183037 is an FDA 510(k) held by Elekta, Inc., substantially equivalent on Dec 4, 2018 after 33 days, with 6 recalls tied to it in FDA's recall database.
- Review time: 33 days
- Recalls: 6
- Cited as a predicate by: 1 device
The Monaco system is used to make treatment plans for patients with prescriptions for external beam radiation therapy. The system calculates dose for photon and electron treatment plans and displays, on-screen and in hard-copy, two- or three-dimensional radiation dose distributions inside patients for given treatment plan set-ups.
- Monaco RTP SystemK190178 · Elekta, Inc. · Mar 29, 2019
| Sep 14, 2021 | Z-2563-2021Contour changes can be saved on an unintended image set. In addition, these contour edits do not cause the dose to be frozen on the plans associated with that image set. | Open |
| Jul 26, 2021 | Z-2406-2021If a couch is removed while a plan is loaded, and then added back to the Studyset when the plan is unloaded, it is possible to calculate dose with the couch unassigned to the beams. | Open |
| Apr 16, 2020 | Z-1825-2020The Monaco RTP Radiation Treatment Planning System may change the shape and volume of the contour potentially resulting in the device delivering an inaccurate dose. | Open |
| Nov 22, 2019 | Z-0670-2020Monaco is using the incorrect energy when optimizing and calculating dose. | Open |
| Sep 4, 2019 | Z-2560-2019It is possible that the forced electron density settings will be changed for some structures unintentionally and this can result in incorrect dose calculation. | Open |
| Feb 8, 2019 | Z-0965-2019If Improve Target Dose was chosen as an optimization model in a previous treatment session, Monaco will automatically use this optimization model again when proceeding with the online plan adaptation of a completion… | Terminated |
- RT Elements (4.6)K261655 · Brainlab SE · Oct 5, 2026
- Virtual Cone (1.0)K260750 · Varian Medical Systems, Inc. · Jul 8, 2026
- RadOncAIK253050 · Informai · Jun 18, 2026
- Multimodality Simulation Workspace (MM Sim) (v1.0.0)K260207 · Philips Medical Systems Nederland B.V. · May 27, 2026
- eXaSkin PlusK252784 · Anatomical Geometry S.L. · May 22, 2026
- ART.1-USK253078 · Seetreat Pty, Ltd. · May 14, 2026
- syngo.via RT Image Suite VC10K252304 · Varian Medical Systems, Inc. · Mar 18, 2026
- Monaco RTP System (6.3)K252002 · Elekta Solutions AB · Feb 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 1, 2018
- Review panel
- Radiology
- Regulation
- 21 CFR 892.5050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files