Teleport Microcatheter
Catheter, Percutaneous. 510(k) K182360, from Orbusneich Medical Trading, Inc. (Fort Lauderdale, FL). Product code DQY, class 2.
As of Nov 19, 2026, K182360 is an FDA 510(k) held by Orbusneich Medical Trading, Inc., substantially equivalent on Nov 9, 2018 after 71 days, with no recalls tied to it in FDA's recall database.
- Review time: 71 days
- Recalls: 0
- Cited as a predicate by: 1 device
catheter design hydrophilic coating 0.014” guidewire compatibility 4F guiding catheter compatibility Maximum allowable pressure of 300 psi EO sterilization The following technological differences exist between the subject and predicate device: specific materials selected exact dimensions of components and catheter permissible rotations Performance Data: Testing was performed to…
- ASAHI Corsair ProK161126 · Asahi Intecc Co., Ltd. · Aug 25, 2016
- Teleport XT MicrocatheterK231608 · OrbusNeich Medical (Shenzhen) Co., Ltd. · Jan 7, 2024
- CrossFAST Integrated Microcatheter Advanced Delivery SystemK262817 · Vantis Vascular, Inc. · Sep 18, 2026
- NHanceITK260559 · IMDS Operation B.V. · Aug 14, 2026
- APRO 35 Swift CatheterK262392 · Alembic, LLC · Aug 12, 2026
- CPS Locator 3D Plus Delivery CatheterK261766 · CenterPoint Systems, LLC · Jul 29, 2026
- SSPC NXT Delivery CatheterK262240 · CenterPoint Systems, LLC · Jul 29, 2026
- Amplatzer TorqVue LP Delivery System; Amplatzer TorqVue LP CatheterK261825 · Abbott · Jul 2, 2026
- Amplatzer TorqVue Exchange SystemK261631 · Abbott Medical · Jun 17, 2026
- Perfect-O Ostial Positioning CatheterK260289 · Balosmark, Inc. · Jun 5, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 30, 2018
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1250
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files