Closed Antineoplastic And Hazardous Drug Reconstitution And Transfer System. 510(k) K181221, from Becton, Dickinson and Company (Franklin Lakes, NJ). Product code ONB, class 2.
As of Nov 19, 2026, K181221 is an FDA 510(k) held by Becton, Dickinson and Company, substantially equivalent on Nov 30, 2018 after 207 days, with 1 recall tied to it in FDA's recall database.
- Review time: 207 days
- Recalls: 1
- Cited as a predicate by: 2 devices
The BD PhaSeal™ Optima system is an airtight and leakproof closed system drug transfer device (CSTD) that mechanically prohibits the transfer of environmental contaminants into the system and the escape of drug vapor concentrations outside the system, thereby minimizing individual and environmental exposure to drug vapor, aerosols and spills.
- BD Phaseal Closed System Transfer DeviceK123213 · Becton, Dickinson & CO · Jan 9, 2013
- BD PhaSeal™ Optima Connecting Set (C83-O); BD PhaSeal™ Optima Spike Set (C180-O)K250059 · Becton, Dickinson and Company · Sep 12, 2025
- BD PhaSeal Optima Closed System Drug Transfer DeviceK201099 · Becton, Dickinson and Company · Aug 12, 2020
| Started | Recall | Status |
|---|---|---|
| Jun 16, 2025 | Z-2453-2025Closed system drug transfer devices were shipped to the U.S. market without a U.S. version of the instructions for use, which could be an issue if a healthcare professional is prompted to review it. | Open |
- ProSeal™ Transfer Injector (421120, 421130, 421140)K251722 · Epic Medical Pte. , Ltd. · Dec 5, 2025
- Chemfort® 28-day 20 mm Vial Adaptor and 13 mm ConvertorK253033 · Simplivia Healthcare , Ltd. · Oct 21, 2025
- BD PhaSeal™ Optima Connecting Set (C83-O); BD PhaSeal™ Optima Spike Set (C180-O)K250059 · Becton, Dickinson and Company · Sep 12, 2025
- Chemfort Female Luer Lock AdaptorK251411 · Simplivia Healthcare , Ltd. · Aug 5, 2025
- ProSeal™ Bag Spike with Additive Port (423370ST, 423370)K251340 · Epic Medical Pte. , Ltd. · May 29, 2025
- ZeroClear™ Bag Access (423100)K243976 · Epic Medical Pte. , Ltd. · Jan 22, 2025
- ProSeal™ Vented Universal Vial AdaptorK240517 · Epic Medical Pte. , Ltd. · Dec 26, 2024
- ProSeal™ Closed System Bag AccessK241988 · Epic Medical Pte. , Ltd. · Oct 23, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 7, 2018
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5440
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files