Voyager Trajectory Array Guide (V-TAG)
Neurological Stereotaxic Instrument. 510(k) K180854, from Voyager Therapeutics, Inc. (Cambridge, MA). Product code HAW, class 2.
As of Nov 19, 2026, K180854 is an FDA 510(k) held by Voyager Therapeutics, Inc., substantially equivalent on Jul 23, 2018 after 112 days, with no recalls tied to it in FDA's recall database.
- Review time: 112 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The V-TAG is intended to assist with stereotactic guidance, placement, and fixation for the operation of surgical instruments or devices during the planning and operation of neurological procedures performed in conjunction with preoperative and perioperative MR imaging. These procedures include laser coagulation, biopsies, catheter placement and electrode placement procedures.
- Monteris Medical UfoK090240 · Monteris Medical, · Aug 6, 2009
- Ball Joint Guide Array (66295)K250893 · Bayer Medical Care, Inc. · Sep 4, 2025
- Voyager Trajectory Array Guide (V-TAG)K191400 · Mri Interventions, Inc. · Jun 21, 2019
- Stereotactic Ultralight System SUSyK261157 · inomed Medizintechnik GmbH · Nov 6, 2026
- StealthStation™ S8 Cranial v2.3.0K262716 · Medtronic Navigation · Nov 6, 2026
- NeuroAlignK261997 · Medivis, Inc. · Oct 26, 2026
- Disposable Reflective Marker Spheres (AM-BK115S, AM-BL130S)K262214 · Guangzhou Aimooe Technology Co., Ltd. · Oct 15, 2026
- Geniant Cranial (Navigated Neurosurgical Positioning Robot)K253856 · Koh Young Technology, Inc. · Sep 10, 2026
- Leksell® Vantage Stereotactic SystemK261932 · Elekta Solutions AB · Aug 5, 2026
- Zeta Navigation SystemK253663 · Zeta Surgical, Inc. · May 1, 2026
- Stealth AXiS Cranial clinical applicationK253379 · Medtronic Navigation, Inc. · Mar 26, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 2, 2018
- Review panel
- Neurology
- Regulation
- 21 CFR 882.4560
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files