Safe Secure Sterilization Pouches and Rolls
Wrap, Sterilization. 510(k) K180139, from Safe Secure Packing Co., Ltd. (Dongguan City, CN). Product code FRG, class 2.
As of Nov 21, 2026, K180139 is an FDA 510(k) held by Safe Secure Packing Co., Ltd., substantially equivalent on Jan 3, 2019 after 350 days, with no recalls tied to it in FDA's recall database.
- Review time: 350 days
- Recalls: 0
- Cited as a predicate by: 1 device
Safe Secure Sterilization Pouches and Rolls are intended to be used to enclose another medical device, in a single or double pouch configuration, that is to be sterilized by a health care provider using: • Gravity steam at 121°C (250°F) for 30 minutes; 25 minutes dry time • Pre-vacuum steam at 132°C (270°F) for 4 minutes; 20 minutes dry time • Pre-vacuum steam at 134°C (273°F) for 3 minutes; 20…
- Safe Secure Sterilization Pouch with Steam and Ethylene Oxide Process IndicatorsK153540 · Safe Secure Packaging Co., Ltd. · Aug 4, 2016
- 3M Comply Hydrogen Peroxide Chemical Indicator 1248K170321 · 3M Company · Aug 14, 2017
- Safe Secure Sterilization Pouches and RollsK242839 · Shenzhen Safesecure Medical Infection Control Tech Co. , Ltd. · Oct 16, 2024
- HALYARD* ARMOR-FLEX* Sterilization Wrap with ASSURE-DRY* Technology; HALYARD* HEAVY-FLEX* Sterilization Wrap with…K261897 · O&M Halyard, Inc. · Jul 2, 2026
- Dukal Crepe Paper Sterilization WrapK252823 · Dukal, LLC · May 28, 2026
- HALYARD* ONE-STEP* Sterilization Wrap; HALYARD* QUICK CHECK* Sterilization Wrap; HALYARD* SEQUENTIAL Sterilization…K253454 · O&M Halyard, Inc. · May 18, 2026
- Sterilization Pouch/RollK251347 · Sterivic Medical Co., Ltd. · Jan 28, 2026
- Self-Seal Sterilization Pouch and RollK251177 · Guangdong Maidi Medical Co., Ltd. · Dec 12, 2025
- Chex-All Sterilization Pouches and TubesK250306 · Propper Manufacturing Co., Inc. · Oct 31, 2025
- Sterilization Pouch and RollK243179 · Yichang Xinxin Paper Products Co., Ltd. · Jun 26, 2025
- GCI Sterilization WrappersK250321 · George Courey, Inc. · Jun 6, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 18, 2018
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.6850
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files