SALVATION Midfoot Nail
Screw, Fixation, Bone. 510(k) K180024, from Wrightmedicaltechnologyinc (Memphis, TN). Product code HWC, class 2.
As of Nov 21, 2026, K180024 is an FDA 510(k) held by Wrightmedicaltechnologyinc, substantially equivalent on Jul 11, 2018 after 189 days, with no recalls tied to it in FDA's recall database.
- Review time: 189 days
- Recalls: 0
- Cited as a predicate by: 1 device
The SALVATION™ Midfoot Reconstruction System is indicated for fracture fixation, osteotomies, reconstruction procedures, non-unions, and fusions of bones in the foot and ankle including the metatarsals, cuneiforms, cuboid, navicular, calcaneus and talus; specific examples include: intramedullary medial column fusion and lateral column fusion resulting from neuropathic osteoarthropathy (Charcot).
- Salvation Beams and Bolts SystemK140741 · Wrightmedicaltechnologyinc · May 15, 2014
- T2 IcfK193366 · Stryker GmbH · Mar 20, 2020
- DuoCore Non-Compressive IM NailK263241 · GM Dos Reis Industria e Comercio Ltda. · Nov 2, 2026
- Ntegrate Threaded Nail SystemK261961 · Nvision Biomedical Technologies · Oct 14, 2026
- OsteoCentric Technologies Cannulated and Soild Fasteners with NutsK263116 · OsteoCentric Technologies · Oct 2, 2026
- Arthrex Beaming SystemK262975 · Arthrex, Inc. · Sep 25, 2026
- DynaNail Helix® Fixation SystemK260995 · MedShape, Inc. · Sep 23, 2026
- F.A.S.T ScrewK254280 · Steps Ortho · Sep 21, 2026
- ActivaScrew™ Cannulated COMK261057 · Bioretec, Ltd. · Sep 4, 2026
- OsteoCoil™ GT Active Compression SystemK260106 · Flower Orthopedics Corporation DBA Conventus Flower Orthoped · Aug 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 3, 2018
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3040
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files