MEVION S250i Proton Beam Radiation Therapy Device
System, Radiation Therapy, Charged-Particle, Medical. 510(k) K172848, from Mevion Medical Systems (Littleton, MA). Product code LHN, class 2.
As of Nov 19, 2026, K172848 is an FDA 510(k) held by Mevion Medical Systems, substantially equivalent on Dec 27, 2017 after 99 days, with 5 recalls tied to it in FDA's recall database.
- Review time: 99 days
- Recalls: 5
- Cited as a predicate by: 1 device
The MEVION S250i is intended to deliver proton radiation therapy treatment to patients with localized tumors or other conditions susceptible to treatment by radiation.
- S-250 Proton Beam Radiation Therapy SystemK120676 · Mevion Medical Systems · Jun 4, 2012
- Proton Therapy System - Proteus 235 (Proteus One, Proteus Plus, Proteus TK2)K152224 · Ion Beam Application S.A. · Aug 9, 2016
- S250-FIT Proton Beam Radiation Therapy Device (S250-FIT)K250986 · Mevion Medical Systems, Inc. · Sep 12, 2025
| Feb 1, 2022 | Z-0827-2022Malfunction of the hand pendant controlling movement of the therapy couch and nozzle may result in unintentional motion. Patient injury is possible if they come in contact with the nozzle or other objects in the… | Open |
| Oct 19, 2020 | Z-0485-2021Treatment beam information disappears on Treatment Console screen while beam delivery continues potential for harm to a patient could occur | Terminated |
| May 15, 2020 | Z-2406-2020Couch Correction moves sent after using a 3D CT scan are partially lost if the previous correction sent or recorded had some of the Couch Correction checkboxes turned off | Terminated |
| Oct 1, 2018 | Z-0705-2019Treatment is allowed to continue (via partials) in situations where dDose1 interlock has tripped | Terminated |
| Jun 29, 2018 | Z-2746-2018QFix has advised Mevion Medical Systems that they are identifying unauthorized combinations of QFix Couch Tops with non-QFix devices in clinical use. The kVue Oen Touch latch consists of a precision latch mechanism that… | Terminated |
- Virtue QaK260597 · ProNova Solutions · Sep 23, 2026
- Probeat-CrK260174 · Hitachi High-Tech Corp. · Jun 11, 2026
- ProBeam 360 Proton Therapy System v3.0K252815 · Varian Medical Systems, Inc. · Apr 23, 2026
- S250-FIT Proton Beam Radiation Therapy Device (S250-FIT)K253406 · Mevion Medical Systems, Inc. · Mar 25, 2026
- S250-FIT Proton Beam Radiation Therapy Device (S250-FIT)K250986 · Mevion Medical Systems, Inc. · Sep 12, 2025
- eMotus Respiratory Motion Management SystemK243900 · Empnia, Inc. · Jun 27, 2025
- P-Cure Proton Therapy System (PPTS)K242418 · P-Cure, Ltd. · May 12, 2025
- Probeat-FrK232032 · Hitachi, Ltd. Radiation Oncology Systems, Kashiwanoha · Jan 12, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 19, 2017
- Review panel
- Radiology
- Regulation
- 21 CFR 892.5050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files