Advantage/Advantage Fit Delivery Device, Lynx Delivery Device, Obtryx Delivery Device (Curved & Halo), Obtryx II Delivery Device (Curved & Halo), Solyx SIS Delivery Device
Instrumentation, Surgical Mesh, Urogynecologic, Stress Urinary Incontinence. 510(k) K172565, from Boston Scientific Corporation (Marlboro, MA). Product code PWJ, class 2.
As of Nov 17, 2026, K172565 is an FDA 510(k) held by Boston Scientific Corporation, substantially equivalent on Dec 20, 2017 after 117 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Dec 20, 2017
- Review time: 117 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Advantage System Delivery Device is intended for use as an aid in insertion, placement, fixation, and anchoring of Advantage surgical mesh during urogynaecological procedures. The Advantage Fit System Delivery Device is intended for use as an aid in insertion, placement, fixation, and anchoring of Advantage Fit surgical mesh during urogynaecological procedures.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Modification To Trelex Mesh Surgical MeshK020110 · Boston Scientific · Apr 3, 2002
- Boston Scientific Surgical MeshK081275 · Boston Scientific Corp · Aug 27, 2008
- Blue Sui SlingK121754 · Boston Scientific Corp · Oct 10, 2012
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Advantage Ultra System, Advantage Fit Ultra System, Lynx Ultra SystemK211223 · Boston Scientific Corporation · Jul 21, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 25, 2017
- Review panel
- Obstetrics/Gynecology
- Regulation
- 21 CFR 884.4910
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files