SporView Rapid Read Biological Indicator
Indicator, Biological Sterilization Process. 510(k) K172432, from Crosstex/Spsmedical, A Division of Cantel Medical (Rush, NY). Product code FRC, class 2.
As of Nov 21, 2026, K172432 is an FDA 510(k) held by Crosstex/Spsmedical, A Division of Cantel Medical, substantially equivalent on Dec 12, 2017 after 123 days, with no recalls tied to it in FDA's recall database.
- Review time: 123 days
- Recalls: 0
The SporView® Rapid Read Biological Indicator is intended to be used with the 3M Attest Auto-Reader to monitor the effectiveness of dynamic-air-removal (prevacuum) steam sterilization cycles of 4 minutes at 132°C. The SporView Rapid Read Biological Indicator provides a final fluorescent result in 3 hours. An optional pH color change is observed after 48 hours.
- Modification To: Attest Rapid Readout Biological Indicator, Mode 1292K090569 · 3M Company · Apr 29, 2009
- Attest Brand Rapid Readout Biological Ind. #129XK926364 · 3M Health Care, Ltd. · Mar 31, 1995
- Celerity 5 HP Biological Indicator (LCB052)K260766 · STERIS Corporation · Apr 8, 2026
- Celerity™ 20 HP Biological IndicatorK252680 · STERIS Corporation · Sep 24, 2025
- Terragene® Bionova® BT20 Biological IndicatorK251122 · Terragene · Aug 4, 2025
- Celerity 5 HP Biological Indicator (LCB052); Celerity 5 HP Challenge Pack (LCB059); Celerity 20 HP Biological Indicator…K251452 · Steris · Jun 6, 2025
- Celerity 5 HP Biological Indicator (LCB052); Celerity 5 HP Challenge Pack (LCB059); Celerity 20 HP Biological Indicator…K250044 · STERIS Corporation · Feb 6, 2025
- Celerity IncubatorK250061 · STERIS Corporation · Feb 6, 2025
- 3M™ Attest™ Super Rapid Steam Extended Cycle Clear Challenge Pack 1492PCDE; 3M™ Attest™ Auto-reader 490; 3M™ Attest™…K243501 · 3M Company · Jan 28, 2025
- Terragene® Bionova® Photon Process Challenge Device with unique-point integrator (PCD225-2);Terragene® Bionova® Photon…K242453 · Terragene S.A. · Dec 12, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 11, 2017
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.2800
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files