CODMAN Hydrocephalus Valves, Catheters & Accessories (Bundled)

Shunt, Central Nervous System And Components. 510(k) K172022, from Codman & Shurtleff, Inc. (Raynham, MA). Product code JXG, class 2.

As of Nov 20, 2026, K172022 is an FDA 510(k) held by Codman & Shurtleff, Inc., substantially equivalent on Oct 3, 2017 after 90 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 90 days
  • Recalls: 1
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Codman HAKIM Precision Valve System is an implantable device that provides constant intraventricular pressure and drainage of cerebral spinal fluid (CSF) for the management of hydrocephalus. The Codman HAKIM Programmable Valve System is an implantable device that provides constant intraventricular pressure and drainages of cerebral spinal fluid (CSF) for the management of hydrocephalus.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K172022, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Dec 14, 2020Z-0724-2021Mislabeled product-Bactiseal Ventricular Catheter with Bactiseal Shunt System(823073) mislabeled as Bactiseal Endoscopic Ventricular Catheter (823087) and vs. versaTerminated

Other JXG clearances

The newest 510(k)s for the same product code; their median review was 267 days; see every JXG device

Record

Type
Traditional
Received
Jul 5, 2017
Review panel
Neurology
Regulation
21 CFR 882.5550

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files