Wedge Microcatheter
Catheter, Percutaneous. 510(k) K172014, from MicroVention, Inc. (Tistin, CA). Product code DQY, class 2.
As of Nov 19, 2026, K172014 is an FDA 510(k) held by MicroVention, Inc., substantially equivalent on Apr 5, 2018 after 276 days, with no recalls tied to it in FDA's recall database.
- Review time: 276 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The Wedge Microcatheter is intended for general intravascular use, including the peripheral, coronary and neuro vasculature for the infusion of diagnostic agents, such as contrast media, and to assist in the delivery of interventional devices, such as the SOFIA 6F Catheter, in the neurovasculature.
- Headway 21 Microcatheter, Model: MC212150SK093160 · MicroVention, Inc. · Nov 5, 2009
- Headway 17 MicrocatheterK083343 · MicroVention, Inc. · Dec 4, 2008
- AXS Offset Delivery Assist CatheterK163259 · Stryker Neurovascular · Jul 28, 2017
- OAB Delivery CatheterK253422 · Cognition Medical Corp. · Oct 2, 2026
- Wedge XL Delivery CatheterK232542 · MicroVention, Inc. · May 16, 2024
- NG Delivery CatheterK230609 · Balt USA, LLC · Sep 13, 2023
- CrossFAST Integrated Microcatheter Advanced Delivery SystemK262817 · Vantis Vascular, Inc. · Sep 18, 2026
- NHanceITK260559 · IMDS Operation B.V. · Aug 14, 2026
- APRO 35 Swift CatheterK262392 · Alembic, LLC · Aug 12, 2026
- CPS Locator 3D Plus Delivery CatheterK261766 · CenterPoint Systems, LLC · Jul 29, 2026
- SSPC NXT Delivery CatheterK262240 · CenterPoint Systems, LLC · Jul 29, 2026
- Amplatzer TorqVue LP Delivery System; Amplatzer TorqVue LP CatheterK261825 · Abbott · Jul 2, 2026
- Amplatzer TorqVue Exchange SystemK261631 · Abbott Medical · Jun 17, 2026
- Perfect-O Ostial Positioning CatheterK260289 · Balosmark, Inc. · Jun 5, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 3, 2017
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1250
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files