ASAHI PTCA Guide Wires, ASAHI Corsair Microcatheter, ASAHI Corsair Pro Microcatheter
Wire, Guide, Catheter. 510(k) K171933, from Asahi Intecc Co., Ltd. (Hagoya-Shi, JP). Product code DQX, class 2.
As of Nov 20, 2026, K171933 is an FDA 510(k) held by Asahi Intecc Co., Ltd., substantially equivalent on Feb 12, 2018 after 229 days, with no recalls tied to it in FDA's recall database.
- Review time: 229 days
- Recalls: 0
- Cited as a predicate by: 6 devices
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA), including use in crossing or assisting in crossing de novo coronary chronic total occlusions (CTO). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
- Asahi Gaia First, Second, ThirdK133865 · Asahi Intecc Co., Ltd. · Mar 18, 2014
- Asahi Ptca Guide Wire, X-TremeK072431 · Asahi Intecc Co., Ltd. · Sep 26, 2007
- ASAHI Fielder XT-A, ASAHI Fielder XT-RK153106 · Asahi Intecc Co., Ltd. · Jun 21, 2016
- Jowire Neo's Ptca Catheter Guidewires, Models AG141000, AG142000, AG143000, AG141002, AG141010, AG14M060 & AG14M050K022762 · Jomed, Inc. · Dec 16, 2002
- Jowire Asahi Ptca Catheter Guide Wires, Models AG145300,141300,142300,132200,14M350,14M345,14M360,143390,141002K031277 · Jomed, Inc. · May 14, 2003
- Asahi Ptca Guide WireK052339 · Asahi Intecc Co., Ltd. · Nov 30, 2005
- Asahi Ultimatebros 3 Ptca Guide WireK101986 · Asahi Intecc Co., Ltd. · Sep 9, 2011
- Asahi Ptca Guide Wire Confianza ProK041531 · Asahi Intecc Co., Ltd. · Aug 3, 2004
- Turnpike catheter, Turnpike Spiral catheter, Turnpike LP catheter, Turnpike Gold catheter, GuideLiner V3 catheter,…K212211 · Vascular Solutions, LLC · Feb 9, 2022
- R350 guidewire, Spectre guidewire, Raider guidewire, Bandit guidewire, Warrior guidewireK212167 · Vascular Solutions, LLC · Feb 9, 2022
- ASAHI PCI Guide Wire ASAHI CONFIANZA PRO 8-20K211898 · Asahi Intecc Co., Ltd. · Dec 8, 2021
- NovaCross CTO MicrocatheterK193322 · Nitiloop , Ltd. · Apr 2, 2020
- ASAHI PTCA Guide Wire ASAHI Gaia NextK192599 · Asahi Intecc Co., Ltd. · Jan 2, 2020
- ASAHI Corsair Pro XSK182420 · Asahi Intecc Co., Ltd. · Dec 20, 2018
- Small Diameter Core Wire (CMAN-000-00); Small Diameter Core Wire (CMAN-000-14)K260168 · Skycade Med Corporation · Oct 16, 2026
- Hyperdrive 35 GuidewireK253146 · Rapid-Medical , Ltd. · Sep 18, 2026
- CROSSLEAD Standard 035 and CROSSLEAD Stiff 035K261281 · Filmecc Co., Ltd. · Sep 3, 2026
- Accoat Guide WireK253667 · Sp Medical A/S · Jul 14, 2026
- Merit MAK Nitinol/Gold-Tungsten Guide WireK261640 · Merit Medical Ireland , Ltd. · Jul 13, 2026
- InQwire Amplatz Guide WireK254137 · Merit Medical Ireland, Ltd. · May 22, 2026
- FMD Peripheral Guide Wire F-14 Flex 6; FMD Peripheral Guide Wire F-14 Tapered 40; FMD Peripheral Guide Wire F-18 Flex…K260544 · FMD Co., Ltd. · Mar 20, 2026
- Enroute 0.014'' Transcarotid GuidewireK253746 · Lake Region Medical · Mar 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 28, 2017
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1330
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files