Supria True64
System, X-Ray, Tomography, Computed. 510(k) K171738, from Hitachi Healthcare Americas Corporation (Twinsburg, OH). Product code JAK, class 2.
As of Nov 27, 2026, K171738 is an FDA 510(k) held by Hitachi Healthcare Americas Corporation, substantially equivalent on Aug 18, 2017 after 67 days, with no recalls tied to it in FDA's recall database.
- Review time: 67 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The Supria True64 system is indicated for head, whole body, and vascular X-ray Computed Tomography applications in patients of all ages. The images can be acquired in either axial, helical, or dynamic modes. The volume datasets acquired by the Supria can be post processed by the system to provide additional information.
- HITACHI Supria Whole-body X-ray CT System Phase 3K163528 · Hitachi Medical Systems America, Inc. · Mar 3, 2017
- SCENARIA ViewK190841 · Hitachi Healthcare Americas · Sep 13, 2019
- Supria True64 Whole-Body X-Ray CT SystemK183291 · Hitachi Healthcare Americas · Feb 1, 2019
- Bunkerhill NCCT CarotidK261206 · BunkerHill Health · Nov 12, 2026
- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 12, 2017
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files