Alere Afinion HbA1c and ACR on Afinion 2 analyzer
Assay, Glycosylated Hemoglobin. 510(k) K171650, from Abbott Rapid Diagnostics (San Diego, CA). Product code LCP, class 2.
As of Nov 20, 2026, K171650 is an FDA 510(k) held by Abbott Rapid Diagnostics, substantially equivalent on Nov 21, 2017 after 169 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 169 days
- Recalls: 2
- Cited as a predicate by: 3 devices
Afinionâ„¢ 2 analyzer is a compact multi-assay analyzer for point-of-care testing, designed to analyze the Afinionâ„¢ test cartridges. Afinionâ„¢ 2 system, consisting of Afinionâ„¢ 2 analyzer and Alere Afinionâ„¢ test cartridges is for in vitro diagnostic use only.
- Alere Afinion HbA1c, Alere Afinion AS100 AnalyzerK151809 · Alere Technologies AS · Sep 25, 2015
- Afinion HbalcK050574 · Axis-Shield Poc AS · Jul 22, 2005
- Afinion Acr and Acr ControlK072409 · Axis-Shield Poc AS · Feb 12, 2008
- Nova Allegro HbA1c Assay, Nova Allegro AnalyzerK221326 · Nova Biomedical Corporation · Nov 22, 2024
- Afinion™ HbA1c, Afinion™ 2 and Alere Afinion™ AS100 AnalyzerK214117 · Abbott Diagnostics Technologies AS · Sep 27, 2023
- Afinion HbA1c Dx on Afinion 2K182988 · Alere Technologies AS · Nov 29, 2018
| Apr 24, 2025 | Z-1830-2025transit delays of certain cold chain products due to severe thunderstorms which may caused the products to be stored outside the recommended labeled storage conditions. This failure could increase the probability of an… | Open |
| Jun 17, 2024 | Z-2736-2024Five Afinion 2 (AF2) Analyzer were incorrectly market configured as Moderate Complexity and distributed to customers. Use of moderately complex assays by waived laboratories could result in erroneous results. | Open |
- Q-Pad Test SystemK231465 · Qurasense · Dec 6, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 5, 2017
- Review panel
- Hematology
- Regulation
- 21 CFR 864.7470
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files