Breathe Technologies Life2000™ Ventilation System
Ventilator, Continuous, Facility Use. 510(k) K170037, from Breathe Technologies (Irvine, CA). Product code CBK, class 2.
As of Nov 19, 2026, K170037 is an FDA 510(k) held by Breathe Technologies, substantially equivalent on Aug 11, 2017 after 219 days, with 13 recalls tied to it in FDA's recall database.
- Review time: 219 days
- Recalls: 13
The Breathe Technologies Life2000™ Ventilation System is intended to provide continuous or intermittent ventilatory support for the care of individuals who require mechanical ventilation. The Life2000 Ventilation System consists of the Life2000 Ventilator and the Life2000 Compressor. The System is intended for use by qualified, trained personnel under the direction of a physician.
- Breathe Technologies LIFE2000 Ventilation SystemK141943 · Breathe Technologies · Jun 12, 2015
- Respcare Hybrid Ne Face Mask, Model Tbd,; Disposable, Model TbdK062019 · Innomed Technologies, Inc./Respcare, Inc. · Aug 17, 2006
| Apr 7, 2025 | Z-1725-2025, Z-1726-2025A cybersecurity vulnerability was discovered through internal testing. | Open |
| Dec 20, 2024 | Z-0886-2025, Z-0887-2025, Z-0885-2025, Z-0884-2025There is an issue with the ventilator battery charger that could lead to an audible and visual alarm. If the alarm is engaged, the ventilator becomes inoperable. | Open |
| Sep 12, 2024 | Z-0046-2025The Life2000 ventilator may fail to initiate the Low Gas Pressure alarm if the pressure gas source (Life2000 compressor, oxygen cylinder or wall source) is not supplied to the ventilator before initiating therapy. | Open |
| May 29, 2024 | Z-2140-2024Potential for certain Life2000 ventilator systems to either fail to charge or have intermittent charging behavior due to damage to the battery charger dongle. Damage of the battery charger dongle prevents the… | Open |
| Jan 25, 2023 | Z-1141-2023, Z-1142-2023, Z-1140-2023, Z-1139-2023There is the potential for patient desaturation events to occur under certain scenarios when the Life2000 ventilation system is connected with an oxygen concentrator. | Open |
| Nov 12, 2020 | Z-0484-2021Under certain conditions, there is a risk for fire. | Terminated |
- Evita (V800); Evita (V600)K253647 · Draegerwerk AG & CO Kgaa · May 7, 2026
- Inbentus VersatileK252663 · Iconic Solutions by Murcia, SL · Apr 14, 2026
- VPAP Pediatric Face MaskK251888 · Hsiner Co., Ltd. · Mar 12, 2026
- Vivo 45 LSK232365 · Oconnell Regulatory Consultants, Inc. · Dec 19, 2025
- F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size A (ONIV117A); F&P OptiNIV…K252173 · Fisher & Paykel Healthcare, Ltd. · Sep 10, 2025
- SV600, SV800 VentilatorK243767 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Aug 28, 2025
- AVEA disposable expiratory filter/water trap (11790)K251133 · Telesair, Inc. · May 8, 2025
- AF531 Oro-Nasal SE Face MaskK243394 · Respironics, Inc. · Dec 30, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 4, 2017
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5895
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files