Coolief* Cooled RF Probe
Probe, Radiofrequency Lesion. 510(k) K163461, from Halyard Health, Inc. (Alpharetta, GA). Product code GXI, class 2.
As of Nov 20, 2026, K163461 is an FDA 510(k) held by Halyard Health, Inc., substantially equivalent on Apr 13, 2017 after 125 days, with no recalls tied to it in FDA's recall database.
- Review time: 125 days
- Recalls: 0
- Cited as a predicate by: 1 device
The COOLIEF* Cooled Radiofrequency Probe is to be used in conjunction with a radiofrequency generator to create lesions in nervous tissue. This device is also indicated for creating radiofrequency lesions of the genicular nerves for the management of moderate to severe knee pain of more than 6 months with conservative therapy, including medication, in patients with radiologically-confirmed…
- Baylis Pain Management Cooled Probe, Model PMPC-18-150-6K053082 · Baylis Medical Co., Inc. · Nov 30, 2005
- COOLIEF Cooled Radiofrequency Kit AdvancedK203066 · Avanos Medical, Inc. · Dec 22, 2020
- Disposable Radiofrequency CannulaK253907 · Abbott Medical · Apr 16, 2026
- STAR RF Ablation SystemK251802 · Merit Medical Systems, Inc. · Feb 13, 2026
- OneRF Trigeminal Nerve Radiofrequency ProbesK251243 · Neuroone Medical Technologies Corp. · Aug 15, 2025
- Disposable RF Electrode (RFDE-5/RFDE-10/RFDE-15/RFDE-20)K242841 · Abbott Medical · May 27, 2025
- OptaBlate BVN Intraosseous Nerve Ablation System (10mm Probe Single Kit); OptaBlate BVN Intraosseous Nerve Ablation…K250213 · Stryker Instruments · May 15, 2025
- RF CannulaK241367 · Shanghai Samedical & Plastic Instruments Co., Ltd. · Jan 23, 2025
- Intracept Intraosseous Nerve Ablation SystemK222281 · Relievant Medsystems, Inc. · Oct 26, 2022
- Intracept Intraosseous Nerve Ablation SystemK213836 · Relievant Medsystems, Inc. · Mar 11, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 9, 2016
- Review panel
- Neurology
- Regulation
- 21 CFR 882.4725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files