Discovery MR750 3.0T and 4 more
System, Nuclear Magnetic Resonance Imaging. 510(k) K163331, from Ge Medical Systems, LLC (Waukesha, WI). Product code LNH, class 2.
As of Nov 20, 2026, K163331 is an FDA 510(k) held by Ge Medical Systems, LLC, substantially equivalent on Mar 17, 2017 after 109 days, with 25 recalls tied to it in FDA's recall database.
- Review time: 109 days
- Recalls: 25+
- Cited as a predicate by: 3 devices
The SIGNA Architect, SIGNA Artist, Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T and the Optima MR450w 1.5T systems are whole body magnetic resonance scanners designed to support high resolution, high signal-to-noise ratio, and short scan times.
- Discovery MR750 3.0T, Discovery MR450 1.5T, Discovery MR750w 3.0T, Optima MR450w 1.5TK160618 · Ge Medical Systems, LLC · Jun 9, 2016
- SIGNA ArchitectK202966 · Ge Healthcare (Ge Medical Systems, LLC) · Nov 13, 2020
- SIGNA ArtistK202238 · Ge Healthcare (Tianjin) Company Limited · Sep 4, 2020
- SIGNA PremierK171128 · Ge Medical Systems, LLC · Jul 14, 2017
| Jun 20, 2025 | Z-2301-2025, Z-2299-2025, Z-2306-2025, Z-2302-2025, Z-2303-2025GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T,… | Open |
| May 23, 2025 | Z-2130-2025GE HealthCare has become aware that gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. As a result, acoustic… | Open |
| Oct 28, 2024 | Z-0517-2025, Z-0519-2025, Z-0518-2025Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. | Open |
| Jun 14, 2024 | Z-2468-2024, Z-2465-2024, Z-2464-2024, Z-2469-2024, Z-2467-2024, Z-2459-2024GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE… | Open |
| Dec 23, 2021 | Z-0600-2022, Z-0594-2022, Z-0591-2022, Z-0593-2022, Z-0602-2022The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. | Open |
| Aug 26, 2021 | Z-0133-2022, Z-0135-2022, Z-0140-2022, Z-0139-2022, Z-0136-2022Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images. | Terminated |
- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 28, 2016
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files