SOMATOM go.Up, SOMATOM go.Now

System, X-Ray, Tomography, Computed. 510(k) K163296, from Siemens Medical Solutions USA, Inc. (Malvern, PA). Product code JAK, class 2.

As of Nov 17, 2026, K163296 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Mar 21, 2017 after 119 days, with 6 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Mar 21, 2017
  • Review time: 119 days
  • Recalls: 6
  • Cited as a predicate by: 1 device

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

This computed tomography system is intended to generate and process cross-sectional images of patients by computer reconstruction of x-ray transmission data. The images delivered by the system can be used by a trained physician as an aid in diagnosis. This CT system can be used for low dose lung cancer screening in high risk populations.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K163296, newest first; each opens FDA's recall record
Mar 7, 2022Z-0962-2022Software error may result in sporadic problems causing scanning workflow interruptions, unexpected user notifications and image artifacts. Sporadic software errors may also occur during interventional workflows. Results…Open, Classified
Mar 3, 2021Z-1253-2021SOMATOM systems-issues in with software syngo.CT VA30A_SP2 or syngo.CT VA30A_SP2a, may result in sporadic problems causing scanning workflow interruptions and unexpected user notifications. Delay in diagnosis or patient…Terminated
Apr 20, 2018Z-1939-2018There is a potential for a software issue that may cause the need for necessary patient rescans.Terminated
Apr 20, 2018Z-1940-2018There is a potential for a software issue that may cause the need for necessary patient rescans.Terminated
Oct 2, 2017Z-0713-2018The table may become unstable if the nuts on the bolts were not adequately tightened and thus have the potential to loosen and several bolts may gradually loosen at the same time.Terminated
Oct 2, 2017Z-0714-2018The table may become unstable if the nuts on the bolts were not adequately tightened and thus have the potential to loosen and several bolts may gradually loosen at the same time.Terminated

Other JAK Clearances

The newest 510(k)s for the same product code; their median review was 237 days; see every JAK device

Record

Type
Traditional
Received
Nov 22, 2016
Review panel
Radiology
Regulation
21 CFR 892.1750

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files