Allura Xper FD series and Allura Xper OR Table series
Interventional Fluoroscopic X-Ray System. 510(k) K162859, from Philips Medical Systems Nederland B.V. (Best Noord-Brabant, NL). Product code OWB, class 2.
As of Nov 20, 2026, K162859 is an FDA 510(k) held by Philips Medical Systems Nederland B.V., substantially equivalent on Dec 2, 2016 after 51 days, with 25 recalls tied to it in FDA's recall database.
- Review time: 51 days
- Recalls: 25+
- Cited as a predicate by: 2 devices
The Allura Xper series and the Allura Xper OR Table series (within the limits of the used OR table) are intended for use on human patients to perform: • Vascular, cardiovascular and neurovascular imaging applications, including diagnostic, interventional and minimally invasive procedures.
- Allura Xper FD series and Allura Xper OR Table seriesK161563 · Philips Medical Systems Nederland B.V. · Jul 29, 2016
- Cardiovascular Angiography SystemK220311 · Allengers Medical Systems Limited · May 3, 2022
- SmartPerfusionK181966 · Philips Medical Systems Nederlands B.V. · Aug 17, 2018
| Jun 29, 2026 | Z-2928-2026Firmware issue potentially leading to loss of geometry movements. | Open |
| Aug 1, 2025 | Z-2503-2025Philips Azurion and Allura systems configured with a 1 Phase Uninterruptible Power Supply (UPS) have the potential of shutting down and/or not starting up, if power to the system is lost. | Open |
| Jun 30, 2025 | Z-2189-2025Potential for temporary loss of imaging (X-ray) functionality due to software issue. | Open |
| Jan 13, 2025 | Z-1078-2025, Z-1076-2025, Z-1083-2025, Z-1079-2025, Z-1085-2025, Z-1080-2025, Z-1077-2025, Z-1081-2025, Z-1084-2025, Z-1086-2025Potential safety issue with the AD7 and AD7X patient tables (both tilt and non-tilt versions) part of the Philips Allura and Azurion systems. During manual repositioning of the patient tabletop, a finger can get… | Open |
| Jan 13, 2025 | Z-1150-2025, Z-1146-2025, Z-1147-2025, Z-1142-2025, Z-1144-2025, Z-1148-2025, Z-1161-2025, Z-1145-2025, Z-1152-2025, Z-1149-2025, Z-1151-2025, Z-1143-2025Possibility of the patient falling from the table related to the mattress used on the patient table. | Open |
- uAngio AVIVA CXK253726 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 21, 2026
- Extron 3;Extron 6K261413 · DRTECH Corporation · Aug 19, 2026
- Zenition 30K254205 · Philips Medical Systems Nederland B.V. · Aug 7, 2026
- Shield System (Siemens 30x40)K260607 · Radiaction , Ltd. · Jul 31, 2026
- SmartCT (R3.0 (L10))K253670 · Philips Medical Systems B.V. · Jul 10, 2026
- C-beamK252735 · Pulmera, Inc. · May 22, 2026
- Intelligent NRK252503 · Canon, Inc. · Apr 30, 2026
- ARTIS icono floor; ARTIS icono biplane; ARTIS icono ceiling; ARTIS phenoK254173 · Siemens Medical Solutions USA, Inc. · Apr 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Oct 12, 2016
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files