Arca
Skip to content
Tools
Tools

Elecsys TSH assay, cobas e 801 Immunoassay analyzer

Radioimmunoassay, Thyroid-Stimulating Hormone. 510(k) K162606, from Roche Diagnostics (Indianapolis, IN). Product code JLW, class 2.

As of Nov 20, 2026, K162606 is an FDA 510(k) held by Roche Diagnostics, substantially equivalent on Jan 23, 2017 after 126 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 126 days
  • Recalls: 3
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

cobas e 801 immunoassay analyzer is intended for the in-vitro determination of analytes in body fluids. Elecsys TSH immunoassay is intended for the in vitro quantitative determination of thyrotropin in human serum and plasma. Measurements of TSH are used in the diagnosis of thyroid or pituitary disorders.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K162606, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 13, 2019Z-0044-2020AssayTips part of the AssayTip/AssayCup Tray Tips used on the cobas e 801 module- may have an Abnormal Internal Structure and lead to Incorrect patient resultsTerminated
Mar 15, 2019Z-1249-2019The firm has confirmed complaints regarding signal drops on the cobas e 801 module after a ProCell II M bottle changeover, which may lead to incorrect medical decisions with respect to diagnostics and patient treatment.Terminated
Apr 3, 2018Z-2136-2018The syringe plunger on the device may be mounted in a tilted position, which applies mechanical stress to the plunger. In the worst case scenario, the plunger may crack leading to impaired syringe function.Terminated

Other JLW clearances

The newest 510(k)s for the same product code; their median review was 209 days; see every JLW device

Record

Type
Traditional
Received
Sep 19, 2016
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1690

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files