VT·One, VT·One 60days
Negative Pressure Wound Therapy Powered Suction Pump. 510(k) K161410, from Carilex Medical, Inc. (Taoyuan City, TW). Product code OMP, class 2.
As of Nov 20, 2026, K161410 is an FDA 510(k) held by Carilex Medical, Inc., substantially equivalent on Oct 13, 2016 after 146 days, with no recalls tied to it in FDA's recall database.
- Review time: 146 days
- Recalls: 0
- Cited as a predicate by: 1 device
Carilex VT·One/VT·One 60days is indicated for patients who benefit from removal of fluids and excess exudates, infectious material, and tissue debris, which may promote wound healing. The VT·One/VT·One 60days suction therapy unit is indicated on use with patients with the following wounds: • Traumatic • Dehisced wounds • Partial-thickness burns • Chronic wounds including pressure ulcers, diabetic…
- Voltera Powered Suction PumpK112853 · Suzric Enterprise Co., Ltd. · Nov 9, 2012
- Prospera Pro-I, Pro-Ii and Pro-Iii Negative Pressure Wound Therapy SystemK112458 · Medica-Rents Co., Ltd. · Jan 5, 2012
- VT Dressing KitsK172725 · Carilex Medical, Inc. · Jun 8, 2018
- Wound VOX NPWT System (V1-01-01); Wound VOX 300ml Collection Canister & Supply Tubing (CC-00-03); Wound VOX Y-Connector…K262232 · Bechtel Medical, Inc. · Nov 6, 2026
- RENASYS-G 15Fr Channel Drain Gauze Dressing Kit (66802257); RENASYS 15Fr Channel Drain Accessory Kit (66802253)K260306 · Smith & Nephew Medical, Ltd. · Oct 30, 2026
- RENASYS ABDO SHIELD Temporary Abdominal Closure Kit (66807747)K261982 · Smith & Nephew Medical, Ltd. · Oct 23, 2026
- MeCare Alpha (MCA2019)K260426 · IVT Medical, Ltd. · Oct 8, 2026
- RENASYS DYNAFLOW Kit (66807741)K261338 · Smith & Nephew Medical, Ltd. · Sep 11, 2026
- ConvaVAC™ Negative Pressure Wound Therapy SystemK253263 · Convatec Limited, Gdc Building · Jun 24, 2026
- Curasys 2 (EMDN0003)K253199 · CG Bio Co., Ltd. · Jun 23, 2026
- Renasys Edge (66803126)K260646 · Smith & Nephew Medical, Ltd. · May 27, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 20, 2016
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4780
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files