Mirragen Advanced Wound Matrix, 4x4”, Mirragen Advanced Wound Matrix, 2x2”, Mirragen Advanced Wound Matrix, 1x6”
Absorbable Synthetic Wound Dressing. 510(k) K161067, from Engineered Tissue Solutions, LLC (Rolla, MO). Product code QSZ, class U.
As of Nov 19, 2026, K161067 is an FDA 510(k) held by Engineered Tissue Solutions, LLC, substantially equivalent on Sep 15, 2016 after 153 days, with no recalls tied to it in FDA's recall database.
- Review time: 153 days
- Recalls: 0
- Cited as a predicate by: 1 device
The Mirragen™ Advanced Wound Matrix is intended for use in the management of wounds. Wound types include: Partial and full-thickness wounds, pressure ulcers, venous ulcers, diabetic ulcers, chronic vascular ulcers, tunneled/ undermined wounds, surgical wounds (donor sites/grafts, post-Moh's surgery, post laser surgery, podiatric, wound dehiscence), trauma wounds (abrasions, lacerations, first and…
- Puracol Plus AG Collagen Microscaffold Wound DressingK071552 · Medline Industries, Inc. · Apr 25, 2008
- Gore Bio-A Wound MatrixK132397 · W. L. Gore & Associates, Inc. · May 7, 2014
- SiOxD Wound MatrixK222189 · Sioxmed, LLC · Nov 18, 2022
- RestrataK261245 · Acera Surgical, Inc. · Oct 16, 2026
- HyalomatrixK261311 · Anika Therapeutics, Inc. · Sep 2, 2026
- LUOFUCON® Wound MatrixK254256 · Huizhou Foryou Medical Devices Co., Ltd. · Aug 18, 2026
- Redermo Wound MatrixK260020 · Beijing Kreate Medical Co., Ltd. · Apr 16, 2026
- NovoSorb BTMK251567 · Polynovo Biomaterials Pty, Ltd. · Jun 20, 2025
- NovoSorb® MTXK242149 · Polynovo Biomaterials Pty, Ltd. · Mar 5, 2025
- SiOxD® Wound MatrixK241660 · Sioxmed, LLC · Jul 5, 2024
- SiOxD Wound MatrixK232847 · Sioxmed, LLC · Dec 18, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 15, 2016
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files