ACCU-CHEK Guide Blood Glucose Monitoring System

System, Test, Blood Glucose, Over The Counter. 510(k) K160944, from Roche Diabetes Care, Inc. (Indianapolis, IN). Product code NBW, class 2.

As of Nov 18, 2026, K160944 is an FDA 510(k) held by Roche Diabetes Care, Inc., substantially equivalent on Aug 31, 2016 after 148 days, with 2 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Aug 31, 2016
  • Review time: 148 days
  • Recalls: 2
  • Cited as a predicate by: 3 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The Accu-Chek Guide Blood Glucose Monitoring System is comprised of the Accu-Chek Guide meter and the Accu-Chek Guide test strips. The Accu-Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K160944, newest first; each opens FDA's recall record
May 13, 2024Z-2174-2024The reason for recall is the meters may show an incorrect measurement unit (mmol/L rather than mg/dL) and may result in the wrong unit of measure. Which may subsequently cause an error in interpreting a result as…Open, Classified
Sep 30, 2019Z-0747-2020Potential power issues with the Accu-Chek Guide Blood Glucose Monitoring System.Terminated

Other NBW Clearances

The newest 510(k)s for the same product code; their median review was 213 days; see every NBW device

Record

Type
Traditional
Received
Apr 5, 2016
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1345

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files