AirLife Autofill Humidification Chamber
Humidifier, Respiratory Gas, (Direct Patient Interface). 510(k) K160764, from Carefusion 2200, Inc. (Vernon Hills, IL). Product code BTT, class 2.
As of Nov 18, 2026, K160764 is an FDA 510(k) held by Carefusion 2200, Inc., substantially equivalent on Aug 25, 2016 after 157 days, with 4 recalls tied to it in FDA's recall database.
- Substantially equivalent: Aug 25, 2016
- Review time: 157 days
- Recalls: 4
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe AirLife Autofill Humidification Chamber is intended to hold water required to humidify breathing gases delivered to any patient using a heated humidifier. The product is single use device, non-sterile and used in professional healthcare environments under a doctor’s supervision and by skilled clinician.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- MR290 Humidification Chamber Single UseK934140 · Fisher & Paykel Electronics , Ltd. · Jan 24, 1994
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- inspired™ Heated Breathing Circuit (510-008); inspired™ Heated Breathing Circuit (510-009); inspired™ Auto-feed…K252066 · Vincent Healthcare Products Limited · Jun 18, 2026
Recalls
Recalls FDA ties to K160764, newest first; each opens FDA's recall record| Nov 29, 2014 | Z-0346-2018Manufacturing error in humidification chamber may cause an overfill/overflow condition of the chamber. The may case a water back-up into the patient circuit resulting in an excessive amount of water entering the… | Terminated |
| Nov 29, 2014 | Z-0345-2018Manufacturing error in humidification chamber may cause an overfill/overflow condition of the chamber. The may case a water back-up into the patient circuit resulting in an excessive amount of water entering the… | Terminated |
| Nov 29, 2014 | Z-0343-2018Manufacturing error in humidification chamber may cause an overfill/overflow condition of the chamber. The may case a water back-up into the patient circuit resulting in an excessive amount of water entering the… | Terminated |
| Nov 29, 2014 | Z-0344-2018Manufacturing error in humidification chamber may cause an overfill/overflow condition of the chamber. The may case a water back-up into the patient circuit resulting in an excessive amount of water entering the… | Terminated |
Other BTT Clearances
The newest 510(k)s for the same product code; their median review was 142 days; see every BTT device- Optiflow Oxygen Kit (AA484J)K262268 · Fisher and Paykel Healthcare Limited · Aug 27, 2026
- Hvt 2.0K254078 · Vapotherm, Inc. · Apr 13, 2026
- FL-10000U Respiratory HumidifierK251448 · Flexicare Medical Limited. · Jan 16, 2026
- Laboratorios Biogalenic Sterile Water for Inhalation, USPK251419 · Laboratorios Biogalenic S.A. DE C.V. · Jan 14, 2026
- Optiflow Switch+ Filtered Nasal Interface with CO2 Sampling (AA042J)K253479 · Fisher & Paykel Healthcare, Ltd. · Dec 19, 2025
- Hudson RCI® Comfort Flo Nasal Cannula Premature, Infant; Hudson RCI® Comfort Flo Plus and Soft Plus Cannula Extra SmallK250312 · Medline Industries, LP · Jul 2, 2025
- Optiflow+ Nasal Cannula - Small (OPT942); Optiflow+ Nasal Cannula - Medium (OPT944); Optiflow+ Nasal Cannula - Large…K251611 · Fisher & Paykel Healthcare, Ltd. · Jun 25, 2025
- Laboratorios Biogalenic Sterile Water for Inhalation, USPK242717 · Laboratorios Biogalenic S.A. DE C.V. · Jan 30, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 21, 2016
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5450
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files