M3290B Philips IntelliVue Information Center iX

Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms). 510(k) K153702, from Philips Medical Systems (Andover, MA). Product code MHX, class 2.

As of Nov 21, 2026, K153702 is an FDA 510(k) held by Philips Medical Systems, substantially equivalent on Jun 13, 2016 after 173 days, with 12 recalls tied to it in FDA's recall database.

  • Review time: 173 days
  • Recalls: 12
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Intended Use The intended use of the Information Center Software is to display physiologic waves, parameters, and trends, format data for strip chart recordings and printed reports, and provide the secondary annunciation of alarms from other networked medical devices at a centralized location.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K153702, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Jul 31, 2026Z-3142-2026, Z-3141-2026Due to software malfunction, patient information system may freeze and become unresponsive.Open
Dec 22, 2025Z-1156-2026A recent software (SW) patch modifies Mobile Event Notification filter settings without providing any indication to the user when upgrading the system.Open
Apr 19, 2024Z-1827-2024Event Catalog information does not save when copied and transferred from one unit to another.Open
Mar 22, 2024Z-1690-2024Possible failure of Uninterruptable Power Supply (UPS) devices supporting the Patient Information Center (PIC) iX system, potential for the associated PIC iX system to shut down due to the lack of power. may lead to the…Open
Feb 28, 2024Z-1386-2024It was found that the Care Assist mobile application (version 4.1.1 and earlier) would not play custom ringtones when iOS device screens were locked with a passcode.Open
Feb 15, 2024Z-3312-2024If the DIVA touch display generates touch inputs without user interaction, due to possibility of the erroneous acknowledgement of a patient alarm, there is a potential for a delay in the detection of a change in a…Open
Nov 28, 2023Z-0731-2024, Z-0732-2024Push notifications may fail to send to the user under certain conditions. This could potentially result in patient harm due to delay in detection of a change in patient condition.Open
Aug 17, 2023Z-2608-2023Patient Information Center (PIC iX) Release 4.x Surveillance Crash Caused by Intel Graphics Driver Error-with a blank screen and subsequently require a manual reboot of the hardware to restart and continue central…Open
Apr 19, 2023Z-0035-2025During extended operation of the MX40 with the PIC iX, the DHCP (Dynamic Host Configuration Protocol) lease can expire on the MX40. If the DHCP lease expires while the device is offline, upon reconnecting with the PIC…Open
Apr 29, 2019Z-1771-2019Infusion Pump Data Storage Accuracy-Data from the BBraun Space LAN or Arcomed UniqueDoc infusion pumps transmitted via the HL7 output interface through the Patient Information Center iX using a LAN driver may be…Terminated

Other MHX clearances

The newest 510(k)s for the same product code; their median review was 207 days; see every MHX device

Record

Type
Traditional
Received
Dec 23, 2015
Review panel
Cardiovascular
Regulation
21 CFR 870.1025

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files