Pump, Portable, Aspiration (Manual Or Powered). 510(k) K153663, from Medela AG (Baar, CH). Product code BTA, class 2.
As of Nov 19, 2026, K153663 is an FDA 510(k) held by Medela AG, substantially equivalent on May 18, 2016 after 149 days, with no recalls tied to it in FDA's recall database.
- Review time: 149 days
- Recalls: 0
- Cited as a predicate by: 1 device
The Medela Vario 8/18/ci Suction Pumps are indicated for aspiration and removal of surgical fluids, tissue (including bone), gases, bodily fluids (including vomit) or infectious materials from a patient's airway or respiratory support system, either during surgery or at the patient’s bed-side.
- Medela Vario 8/18/CI Secretion & Surgical AspiratorK061205 · Medela AG · Jun 21, 2006
- Medela Vario Suction PumpsK061435 · Medela AG · Jun 8, 2006
- ExsaltaK221676 · Drw Medical · Sep 16, 2022
- Nasal Aspirator (TLC-N02); Electric NoseFrida Pro (12300400); Electric NoseFrida (12100401)K262822 · Zhongshan GL Electronics Co. , Ltd. · Oct 7, 2026
- Momcozy Nasal Aspirator (BN007)K253629 · Shenzhen Root Innovation Technology Co., Ltd. · May 26, 2026
- Baby Nasal Aspirator (BN006, BN006-A, BN006-B, BN006-C, BN006-D, BN02; BN008, BN008-A, BN008-B, BN008-C, BN008-D,…K260134 · Shenzhen Root Innovation Technology Co., Ltd. · May 15, 2026
- Suction Pump (SU-90)K260892 · Shenzhen HugeMed Medical Technical Development Co., Ltd. · May 14, 2026
- Electric nasal aspirator (BC027, BC030, BC033, BC035, BC035B)K260473 · Shenzhen Kingboom Technology Co., Ltd. · May 12, 2026
- Electric Nasal Aspirator (DT10 and DT50, DX80, DX85, DX86 and DX90)K253107 · Shenzhen Dongjiang Technology Co., Ltd. · Apr 14, 2026
- Electric nasal aspirator (BC026, BC025, BC023, BC028, BC029, BC036)K260147 · Shenzhen Kingboom Technology Co., Ltd. · Mar 13, 2026
- Baby Nasal Aspirator (BN002); Baby Nasal Aspirator (BN006); Baby Nasal Aspirator (BN007); Baby Nasal Aspirator (BN008);…K251450 · Shenzhen Desida Technology Co., Ltd. · Jun 6, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 21, 2015
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4780
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files