MaxO2ME
Analyzer, Gas, Oxygen, Gaseous-Phase. 510(k) K153659, from Maxtec, LLC (Salt Lake City, UT). Product code CCL, class 2.
As of Nov 17, 2026, K153659 is an FDA 510(k) held by Maxtec, LLC, substantially equivalent on Jun 10, 2016 after 172 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jun 10, 2016
- Review time: 172 days
- Recalls: 0
- Cited as a predicate by: 3 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe MaxO 2ME oxygen monitor is intended for continuous monitoring of the concentration of oxygen being delivered to patients ranging from newborns to adults. It can be used in the pre-hospital, hospital and sub- acute settings. The MaxO 2ME is not intended as a life supporting device.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Precision Oxygen MonitorK063096 · Precision Medical, Inc. · Feb 27, 2007
Cited as a Predicate
3 later 510(k) summaries name this device as a predicate- Maxtec MaxBlend2+pK231895 · Maxtec, LLC · Dec 4, 2023
- Maxtec MaxO2 ME+pK221734 · Maxtec, LLC · Apr 1, 2023
- OxyMinderK213948 · Bio-Med Devices, Inc. · Mar 17, 2022
Other CCL Clearances
The newest 510(k)s for the same product code; their median review was 112 days; see every CCL device- PRO2 Elite Plus Oxygen Analyzer (PRO2PLUS-1)K261389 · Salter Labs · Jul 30, 2026
- OxyMinder Pro (10310)K251245 · Bio-Med Device, Inc. · Aug 11, 2025
- Smart Check O2 (MA0236)K250002 · Life Spark Medical, LLC · Apr 24, 2025
- Maxtec MaxO2 ME+pK221734 · Maxtec, LLC · Apr 1, 2023
- Percent Oxygen SensorsK213933 · Careox, LLC · Aug 19, 2022
- OxyMinderK213948 · Bio-Med Devices, Inc. · Mar 17, 2022
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 21, 2015
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.1720
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files