MAGNETOM Spectra
System, Nuclear Magnetic Resonance Imaging. 510(k) K153447, from Siemens Medical Solutions USA, Inc. (Malvern, PA). Product code LNH, class 2.
As of Nov 20, 2026, K153447 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Mar 31, 2016 after 125 days, with 1 recall tied to it in FDA's recall database.
- Review time: 125 days
- Recalls: 1
The MAGNETOM Spectra is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and/or spectra, and that displays the internal structure and/or function of the head, body, or extremities. Other physical parameters derived from the images and/or spectra may also be produced.
- Magnetom Aera With Software Syngo Mr E11A, Magnetom Skyra With Software Syngo Mr E11A, Magnetom Skyra With 24 RF ChannelK141977 · Siemens Medical Solutions USA, Inc. · Nov 19, 2014
- Magnetom SpectraK121160 · Siemens Medical Solutions USA, Inc. · Jul 16, 2012
| Started | Recall | Status |
|---|---|---|
| Sep 1, 2023 | Z-2648-2023In some cases, when lubricating grease is present within the headband of the over-ear headphones, it may cause visible, dot- or lineshaped, fat-isointense artifacts during head examinations only. These potential… | Open |
- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Nov 27, 2015
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files