Solid State X-Ray Imager (Flat Panel/Digital Imager). 510(k) K153312, from Canon, Inc. (Tokyo, JP). Product code MQB, class 2.
As of Nov 20, 2026, K153312 is an FDA 510(k) held by Canon, Inc., substantially equivalent on Jun 28, 2016 after 224 days, with no recalls tied to it in FDA's recall database.
- Review time: 224 days
- Recalls: 0
- Cited as a predicate by: 1 device
As a part of the CXDI series radiography system, the CXDI Control Software when used with a compatible CXDI detector is intended to provide digital image capture, processing, and display for conventional film/screen radiographic examinations.
- Digital RadiographyK102012 · Canon Inc. -Medical Equipment Group · Aug 17, 2010
- Digital RadiographyK103591 · Canon Inc. -Medical Equipment Group · Mar 29, 2011
- Digital RadiographyK111682 · Canon Inc. -Medical Equipment Group · Sep 2, 2011
- Digital RadiographyK112309 · Canon Inc. -Medical Equipment Group · Sep 2, 2011
- Digital Radiography CXDI-701C Wireless, Digital Radiography CXDI-70IG Wireless, Digital Radiography CXDI-801C Wireless,K131106 · Canon, Inc. · Jul 3, 2013
- Digital Radiography CXDI-401C WirelessK133693 · Canon, Inc. · Jul 1, 2014
- Philips Eleva WorkspotK140771 · Philips Medical Systems Dmc GmbH · Apr 25, 2014
- Enhanced Feature Software Pack CXDI SeriesK190368 · Canon, Inc. · Mar 13, 2019
- 0909FCE, 0909FCE-HSK253800 · Rayence Co., Ltd. · Jul 31, 2026
- Vivix-S 4386W (FXRD-4386WA)K260820 · Vieworks Co., Ltd. · Jun 18, 2026
- Universal 1417PIK252996 · Konica Minolta Healthcare Americas, Inc. · Jun 12, 2026
- Lux HD 2530 detector (Lux HD 2530)K252911 · Iray Imaging Technology (Haining) Limited · Oct 9, 2025
- Yushan X-Ray Flat Panel DetectorK250211 · Innocare Optoelectronics Corp. · Jul 22, 2025
- Skr 3000K250665 · Konica Minolta, Inc. · Jun 17, 2025
- Wireless/ Wired X-Ray Flat Panel DetectorsK243734 · Allengers Medical Systems Limited · Apr 18, 2025
- Expd 114; Expd 114G; Expd 114P; Expd 114PGK242770 · DRTECH Corporation · Mar 20, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 17, 2015
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1680
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files