Fogarty Occlusion Catheter
Catheter, Intravascular Occluding, Temporary. 510(k) K152762, from Edwards Lifesciences, LLC (Irvine, CA). Product code MJN, class 2.
As of Nov 18, 2026, K152762 is an FDA 510(k) held by Edwards Lifesciences, LLC, substantially equivalent on Nov 23, 2015 after 60 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Nov 23, 2015
- Review time: 60 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFFogarty Occlusion Catheters are indicated for temporary vessel occlusion. The Large Occlusion catheters are intended to be used for temporary occlusion in the aorta, vena cava, and internal jugular vein. The Small Occlusion catheters are intended to be used for temporary occlusion in the peripheral vascular system.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Fogarty Occlusion CatheterK093911 · Edwards Lifesciences, LLC · Jan 21, 2010
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- Fogarty Occlusion CatheterK211610 · Edwards Lifesciences, LLC · Feb 14, 2022
- REBOA Balloon CatheterK160598 · NuMED, Inc. · Jun 20, 2016
Other MJN Clearances
The newest 510(k)s for the same product code; their median review was 130 days; see every MJN device- pREBOA-PRO CatheterK243795 · Prytime Medical Devices, Inc. · Sep 5, 2025
- Bridge Plus Occlusion Balloon (590-002)K251358 · Philips Image Guided Therapy Devices · Jun 24, 2025
- LANDMARK REBOA CatheterK214060 · Zien Medical Technologies, Inc. · Sep 19, 2022
- Fogarty Occlusion CatheterK211610 · Edwards Lifesciences, LLC · Feb 14, 2022
- RenovoCathK212324 · Renovorx, Inc. · Aug 23, 2021
- AortaSTAT Occlusion DeviceK210602 · Renalpro Medical, Inc. · Jul 9, 2021
- Neurescue deviceK210358 · Neurescue Aps · May 21, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 24, 2015
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.4450
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files