VERIFY STEAM Integrating Indicator
Indicator, Physical/Chemical Sterilization Process. 510(k) K152630, from STERIS Corporation (Mentor, OH). Product code JOJ, class 2.
As of Nov 23, 2026, K152630 is an FDA 510(k) held by STERIS Corporation, substantially equivalent on May 12, 2016 after 240 days, with 1 recall tied to it in FDA's recall database.
- Review time: 240 days
- Recalls: 1
- Cited as a predicate by: 3 devices
The integrating indicator is designed to chemically react over time with the critical parameters of steam sterilization cycle within a specified tolerance. The integrating indicator strip is intended to be placed in each pack, pouch, container, tray or other containment device to function as an independent monitor of critical parameters for the following sterilization cycles: Steam Sterilization…
- Steam Sterilization IntergratorK012195 · Dana Products, Inc. · May 7, 2002
- VERIFY STEAM Integrating Indicator, VERIFY STEAM Integrating Indicator 5CMK213412 · Steris Corparation · Jan 21, 2022
- Getinge Assured MI Steam Migrating IntegratorK200252 · Steritec Products Mfg Co, Inc. · May 21, 2020
- VERIFY STEAM Integrating Indicator - ShortK162631 · STERIS Corporation · Jan 27, 2017
| Started | Recall | Status |
|---|---|---|
| May 25, 2022 | Z-1793-2022Facility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lots received between 06/01/21-9/30/21. | Open |
- Endox Test StripsK263267 · Ibt Scientific · Oct 16, 2026
- 3M™ Attest™ Steam Chemical Integrator (1243A, 1243B, 1243RE, 1243RES)K261992 · Solventum US, LLC · Sep 25, 2026
- LF Process Indicator Tape for Steam SterilizationK260181 · Intertape Polymer Group · Feb 20, 2026
- SafeSecure Steam Sterilization Process Indicator (4012, 4013, 4014, 4016); SafeSecure Vaporized Hydrogen Peroxide…K251991 · Shenzhen Safesecure Medical Infection Control Tech Co. , Ltd. · Dec 23, 2025
- DISINTEK™ PA Test StripsK251035 · Serim Research · Jun 3, 2025
- Rapicide PA High-Level Disinfection Test Strip Model Ref # = ML02-0118K251048 · STERIS Corporation · May 2, 2025
- VERIFY STEAM Integrating IndicatorK243876 · STERIS Corporation · Apr 25, 2025
- Green Card Bowie-Dick Test (BD115)K250172 · Steritec Products, Inc. (A Getinge Company) · Feb 20, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 15, 2015
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.2800
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files