IS4000 Stapler 30 Instrument and Stapler 30 Reloads
System, Surgical, Computer Controlled Instrument. 510(k) K152421, from Intuitive Surgical, Inc. (Sunnyvale, CA). Product code NAY, class 2.
As of Nov 18, 2026, K152421 is an FDA 510(k) held by Intuitive Surgical, Inc., substantially equivalent on Mar 4, 2016 after 191 days, with 3 recalls tied to it in FDA's recall database.
- Review time: 191 days
- Recalls: 3
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe Intuitive Surgical EndoWrist® Stapler 30 Instrument and Stapler 30 reloads are intended to be used with the da Vinci Surgical System (Model IS4000) for resection, transection and/or creation of anastomoses in General, Thoracic, Gynecologic, and Urologic surgery. The device is indicated for adult and pediatric use. The device can be used with staple line or tissue buttressing material.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Endowrist Stapler 45 and Stapler 45 ReloadsK140553 · Intuitive Surgical, Inc. · Jul 25, 2014
- Endopath Endocutter Gray Cartridge, Model 6R45M/GRAY Cartridge ReloadK033269 · Ethicon Endo-Surgery, Inc. · Dec 10, 2003
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- IS4000 Stapler 45 Instrument and its Reusable Accessories, IS4000 EndoWrist Stapler 30 Instrument, IS3000 Stapler 45…K170879 · Intuitive Surgical, Inc. · Sep 21, 2017
- EndoWrist Stapler 45 Instrument, EndoWrist Stapler 45 Reloads, EndoWrist Stapler 30 Instrument, EndoWrist Stapler 30…K170508 · Intuitive Surgical, Inc. · Mar 10, 2017
Recalls
Recalls FDA ties to K152421, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Jul 14, 2016 | Z-2349-2016, Z-2350-2016An increase in the number of da Vinci EndoWrist Stapler complaints where the customer experienced a Stapler Firing Failed message as well as review of da Vinci Xi Surgical System logs found an increased trend | Terminated |
| Jul 14, 2016 | Z-2677-2016Field failures were reported related to the da Vinci Xi Surgical System EndoWrist Stapler 45 and 30 instruments having an interruption in shaft rotation and / or instrument jaws not opening. | Terminated |
Other NAY clearances
The newest 510(k)s for the same product code; their median review was 89 days; see every NAY device- da Vinci Xi Surgical System (IS4000);da Vinci X Surgical System (IS4200)K263592 · Intuitive Surgical, Inc. · Oct 30, 2026
- da Vinci Surgical System, Model IS5000K261823 · Intuitive Surgical, Inc. · Sep 8, 2026
- da Vinci Surgical System, Model IS5000K261824 · Intuitive Surgical, Inc. · Jul 31, 2026
- da Vinci Firefly Imaging SystemK260695 · Intuitive Surgical · May 22, 2026
- Senhance Ultrasonic SystemK254192 · Asensus Surgical · May 12, 2026
- da Vinci Force Feedback InstrumentsK253986 · Intuitive Surgical, Inc. · Mar 11, 2026
- da Vinci Surgical System (IS5000)K251739 · Intuitive Surgical, Inc. · Jan 16, 2026
- da Vinci SP Surgical System (SP1098); da Vinci E-200 GeneratorK253556 · Intuitive Surgical, Inc. · Jan 16, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 26, 2015
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.1500
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files