Pentacam AXL
Device, Analysis, Anterior Segment. 510(k) K152311, from Oculus Optikgerate GmbH (Wetzla, DE). Product code MXK, class 2.
As of Nov 20, 2026, K152311 is an FDA 510(k) held by Oculus Optikgerate GmbH, substantially equivalent on Jan 20, 2016 after 159 days, with 3 recalls tied to it in FDA's recall database.
- Review time: 159 days
- Recalls: 3
- Cited as a predicate by: 3 devices
The Pentacam® is designed to take photos of the anterior segment of the eye which includes the cornea, pupil, anterior chamber and lens of the eye. To evaluate: - corneal shape, - analyze condition of the lens (opaque crystalline lens), - analyze the anterior chamber angle, - analyze anterior chamber depth, - analyze the volume of the anterior chamber, - analyze anterior or posterior cortical…
- Iolmaster 500K122418 · Carl Zeiss Meditec, AG · Apr 12, 2013
- Pentacam Scheimpflug CameraK030719 · Oculus Optikgerate GmbH · Sep 16, 2003
- Myopia MasterK202989 · Oculus Optikgeräte GmbH · Jul 14, 2021
- Pentacam AXL WaveK201724 · Oculus Optikgerate GmbH · Oct 21, 2020
- Galilei G6 Lens ProfessionalK182659 · Sis Ag, Surgical Instrument Systems · Jul 25, 2019
| Aug 8, 2023 | Z-2483-2023Their is a potential that optical devices with insufficient anti-reflective coating may lead to incorrect axial length measurements. | Open |
| Jul 8, 2022 | Z-1673-2022Due to a software issue, IOL calculator printout often does not accurately reflect the alignment axis and incision position when planning toric IOLs | Open |
| Nov 21, 2017 | Z-0635-2018The device software versions have an anomaly which may produce an erroneous marking for the quality specification value | Terminated |
- Pentacam® Cornea OCTK251848 · Oculus Optikgeräte GmbH · Mar 13, 2026
- Tomey Optical Biometer OA-2000 (OA-2000)K252348 · Tomey Corporation · Dec 18, 2025
- Boss™K223700 · Intelon Optics, Inc. · Aug 16, 2024
- MyahK222933 · Visia Imaging S.R.L. · Jun 29, 2023
- MyahK211868 · Visia Imaging S.R.L. · Mar 1, 2022
- Myopia MasterK202989 · Oculus Optikgeräte GmbH · Jul 14, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 14, 2015
- Review panel
- Ophthalmic
- Regulation
- 21 CFR 886.1850
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files