MAGNETOM Aera (24-channel), MAGNETOM Avanto fit, MAGNETOM Skyra fit, MAGNETOM Prisma, MAGNETOM Prisma fit
System, Nuclear Magnetic Resonance Imaging. 510(k) K151579, from Siemens Medical Solutions USA, Inc. (Mavern, PA). Product code LNH, class 2.
As of Nov 20, 2026, K151579 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Sep 29, 2015 after 110 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 110 days
- Recalls: 2
- Cited as a predicate by: 1 device
The MAGNETOM systems are indicated for use as magnetic resonance diagnostic devices (MRDD) that produce transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and/or spectra, and that display the internal structure and/or function of the head, body or extremities. Other physical parameters derived from the images and/or spectra may also be produced.
- Magnetom Aera With Software Syngo Mr E11A, Magnetom Skyra With Software Syngo Mr E11A, Magnetom Skyra With 24 RF ChannelK141977 · Siemens Medical Solutions USA, Inc. · Nov 19, 2014
- MAGNETOM Aera, MAGNETOM Skyra, MAGNETOM Prisma, MAGNETOM Prisma fitK153343 · Siemens Medi Cal Solutions, Inc. · Apr 15, 2016
| Started | Recall | Status |
|---|---|---|
| Aug 28, 2025 | Z-2659-2025, Z-2661-2025There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a… | Open |
- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 11, 2015
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files