MicroCutter XCHANGE 30 Stapler, MicroCutter XCHANGE 30 Blue Cartridge, MicroCutter XCHANGE 30 White Cartridge
Staple, Implantable. 510(k) K151081, from Cardica, Inc. (Redwood City, CA). Product code GDW, class 2.
As of Nov 20, 2026, K151081 is an FDA 510(k) held by Cardica, Inc., substantially equivalent on Jan 15, 2016 after 268 days, with no recalls tied to it in FDA's recall database.
- Review time: 268 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The MicroCutter XCHANGE® 30 is intended for transection and resection in multiple open or minimally invasive urologic, thoracic, and pediatric surgical procedures, as well as application for transection, resection, and/or creation of anastomoses in the small and large intestine, and the transection of the appendix.
- Proximate and Endopath Linear Cutters and StaplersK020779 · Ethicon Endo-Surgery, Inc. · Jun 5, 2002
- Endopath ETS45, Ets FLEX45, Ets Compact-FLEX45 Linear Cutters, Ets FLEX45 and Ets Compact-FLEX45 No-Knife ArticulatingK002398 · Ethicon Endo-Surgery, Inc. · Nov 3, 2000
- Microcutter Xchange 30, Microcutter Xchange 30, Blue Staple Cartridge, Blue Staple CartridgeK132581 · Cardica, Inc. · Jan 7, 2014
- Dextera MicroCutter 30 Blue Reload, Dextera MicroCutter 30 Curved Tip Blue Reload, Dextera MicroCutter 30 White Reload,…K171561 · Dextera Surgical, Inc. · Aug 28, 2017
- Dextera MicroCutter 5/80 Blue Reload, Dextera MicroCutter 5/80 Blue Curved Tip ReloadK161137 · Cardica, Inc. · Jul 20, 2016
- Tendon AnchorK263461 · Smith & Nephew, Inc. · Oct 27, 2026
- easyEndo™ E-Lite Single Use Powered Endoscopic Staplers; easyEndo™ E-Lite Single Use Powered Endoscopic Staplers with…K254291 · Ezisurg Medical Co., Ltd. · Sep 25, 2026
- ETHICON™ Circular Stapler (CDH21mm); ETHICON™ Circular Stapler (CDH25mm); ETHICON™ Circular Stapler (CDH29mm); ETHICON™…K260196 · Ethicon Endo-Surgery, LLC · May 11, 2026
- Tri-staple 2.0™ Reloads; Endo GIA™ Reloads with Tri-Staple™ Technology; Endo GIA™ Gray Articulating Reloads; Signia™…K253657 · Covidien (Part of Medtronic) · Apr 10, 2026
- ETHICON™ 4000 45mm Compact Stapler (EC3DT45C); ETHICON™ 4000 45mm Standard Stapler (EC3DT45S); ETHICON™ 4000 45mm Long…K252739 · Ethicon Endo-Surgery, LLC · Dec 17, 2025
- ETHICON 4000 60mm Compact Stapler (EC3D60C); ETHICON 4000 60mm Standard Stapler (EC3D60S); ETHICON 4000 60mm Long…K250835 · Ethicon Endo-Surgery, LLC · May 14, 2025
- ECHELON LINEAR™ Stapler 30mm Stapler (GTX30); ECHELON LINEAR™ Stapler 60mm Stapler (GTX60); ECHELON LINEAR™ Stapler…K243276 · Ethicon Endo-Surgery, LLC · Feb 25, 2025
- ECHELON 4000 60mm Compact Stapler (EC3D60C); ECHELON 4000 60mm Standard Stapler (EC3D60S); ECHELON 4000 60mm Long…K241630 · Ethicon Endo-Surgery, LLC · Oct 28, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 22, 2015
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files