ProTrack RF Anchor Wire
Catheter, Septostomy. 510(k) K150709, from Baylis Medical Company, Inc. (Mississauga, CA). Product code DXF, class 2.
As of Nov 21, 2026, K150709 is an FDA 510(k) held by Baylis Medical Company, Inc., substantially equivalent on Jun 17, 2015 after 90 days, with 1 recall tied to it in FDA's recall database.
- Review time: 90 days
- Recalls: 1
- Cited as a predicate by: 3 devices
The ProTrack RF Anchor Wire is indicated for the creation of an atrial septal defect in the heart.
- Baylis Medical RF Septostomy Generator, Nykanen RF Septostomy Catheter, Baylis Medical Connector CableK990284 · Baylis Medical Co., Inc. · Feb 1, 2001
- Nrg Transseptal NeedleK073326 · Baylis Medical Co., Inc. · May 28, 2008
- LightningWire Transseptal Puncture System (TPS)K261745 · ElectroWire Medical · Jun 26, 2026
- VersaCross™ RF WireK242076 · Baylis Medical Company · Nov 1, 2024
- HOTWIRE™ RF GuidewireK240900 · Atraverse Medical · May 1, 2024
| Started | Recall | Status |
|---|---|---|
| Jun 10, 2025 | Z-2103-2025Potential for hole in the Tyvek layer of the sterile barrier pouch, which may compromise device sterility. Issue could potentially lead to systemic infection and sepsis in worst case scenario. Potential punctures may go… | Open |
- LightningWire Transseptal Puncture System (TPS)K261745 · ElectroWire Medical · Jun 26, 2026
- SafeSept RF Transseptal Guidewire (SSRF132; SSRF132R; SSRF232; SSRF232R; SSRF135; SSRF135R; SSRF235; SSRF235R)K253799 · Pressure Products Medical Device Manufacturing, LLC · Mar 13, 2026
- Hotwire RF Guidewire (901XXX); Hotwire RF Guidewire (902XXX)K260292 · Atraverse Medical · Feb 27, 2026
- Hotwire RF Guidewire (901XXX); Hotwire RF Guidewire (902XXX)K252419 · Atraverse Medical, Inc. · Aug 27, 2025
- CrossWise RF Transseptal Access System (Models: CW-1085S, CW-1085A, CW-1012W, CW-1012C, CW-1085C, CW-1085V, CW-1013F)K251007 · Circa Scientific, Inc. · May 1, 2025
- Cross Wise™ Multi-Use RF Adapter CableK243193 · Circa Scientific, Inc. · Nov 26, 2024
- VersaCross™ RF WireK242076 · Baylis Medical Company · Nov 1, 2024
- CrossWise RF Transseptal Access System (Models: CW-1085S, CW-1085A, CW-1012W, CW-1012C); CrossWise RF Adapter Cable…K241414 · Circa Scientific, Inc. · Sep 26, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 19, 2015
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.5175
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files